Share:

MINORS BR. RD over MINORS BRANCH

Map

Coordinates:
+37.53389, -84.96250
37°32'02" N, 84°57'45" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:MINORS BR. RD over MINORS BRANCH
Structure number:011C00050N
Location:1.4 M. S JCT KY 37
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:40.0 ft. [12.2 m]
Total length:44.0 ft. [13.4 m]
Roadway width between curbs:23.3 ft. [7.1 m]
Deck width edge-to-edge:24.6 ft. [7.5 m]
Skew angle:45°
Owner:County Highway Agency [02]
Year built:1991
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Box beam or girders - Multiple [05]
Deck type:Concrete Precast Panels [2]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: September 2018

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:75 [as of 2006]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:44.3
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$99,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2018PoorSatisfactoryGoodPoor7544.3
September 2016GoodGoodGoodGood7594.9
September 2014GoodGoodGoodGood7595.9
October 2012GoodGoodGoodGood7585.4
October 2010FairSatisfactorySatisfactorySatisfactory7585.4
October 2008FairSatisfactorySatisfactorySatisfactory7585.4
October 2006FairSatisfactorySatisfactorySatisfactory7785.4
October 2004FairGoodSatisfactorySatisfactory4586.7

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.352351100
Deck
Prestressed Concrete Top Flangesq. ft.1,0891,0543500
Substructure
Reinforced Concrete Abutmentlinear ft.109102430
Reinforced Concrete Pile Cap/Footinglinear ft.926120011
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.8480400
Steel Protective Coatingsq. ft.420420000