Share:

DRY FORK ROAD over DRY FORK CREEK

Map

Coordinates:
+37.66806, -84.90583
37°40'05" N, 84°54'21" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:DRY FORK ROAD over DRY FORK CREEK
Structure number:011C00067N
Location:1.0 MI N OF JCT W/US 150
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:24.0 ft. [7.3 m]
Total length:24.0 ft. [7.3 m]
Owner:County Highway Agency [02]
Year built:2006
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Concrete [1]
Main span design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: September 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Structural appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:97.0

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
September 2018Fair6 out of 10-97.0
September 2016Fair6 out of 105397.0
September 2014Good8 out of 105375.0
October 2012Good8 out of 10-75.0
October 2010Good8 out of 10-74.0
October 2008Good8 out of 105374.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Reinforced Concrete Pile Cap/Footinglinear ft.43031120
Culvert
Reinforced Concrete Culvertlinear ft.24121200