Share:

I-275 EB over RELOC. THREE MILE RD.

Map

Coordinates:
+39.04389, -84.46778
39°02'38" N, 84°28'04" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-275 EB over RELOC. THREE MILE RD.
Structure number:019B00046R
Old structure number:019*0275*B0046P (from 1992 edition)
Location:EBL .25 WEST OF I-471
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:58.1 ft. [17.7 m]
Total length:163.1 ft. [49.7 m]
Roadway width between curbs:56.1 ft. [17.1 m]
Deck width edge-to-edge:57.1 ft. [17.4 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1974
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: August 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:41,789 [as of 2016]
Truck traffic:6% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:96.0
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$1,218,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2017FairSatisfactoryGoodGood4178996.0
August 2015FairSatisfactoryGoodGood3727896.0
August 2013FairSatisfactoryGoodGood3168096.0
August 2011FairFairGoodGood3310091.8
February 2010FairFairGoodGood2900092.2
January 2008FairFairGoodGood7710087.5
October 2005GoodGoodGoodGood7537586.6
October 2003GoodGoodVery GoodGood2065894.0
October 2001GoodGoodVery GoodGood2065892.0
August 1999GoodGoodVery GoodGood2065892.0
September 1997GoodGoodVery GoodGood2065892.0
November 1995GoodGoodVery GoodGood2065888.2
October 1993GoodGoodVery GoodGood2065888.2
August 1991GoodGoodVery GoodGood2065888.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.1,4671,464120
Deck
Reinforced Concrete Top Flangesq. ft.9,2919,19110000
Wearing Surfacessq. ft.9,1339,133000
Substructure
Reinforced Concrete Columneach88000
Reinforced Concrete Abutmentlinear ft.121991930
Reinforced Concrete Pier Caplinear ft.116115100
Joints
Pourable Jointlinear ft.114645000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.3263111500