Share:

CS-1204 over CSX RAILROAD

Map

Coordinates:
+39.08139, -84.49167
39°04'53" N, 84°29'30" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CS-1204 over CSX RAILROAD
Structure number:019C00057N
Location:200' EAST JCT KY 9
Purpose:Carries highway over railroad
Route classification:Local (Urban) [19]
Length of largest span:132.9 ft. [40.5 m]
Total length:804.2 ft. [245.1 m]
Roadway width between curbs:25.9 ft. [7.9 m]
Deck width edge-to-edge:33.8 ft. [10.3 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Skew angle:
Owner:County Highway Agency [02]
Year built:1989
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:4
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: January 2018

Good/Fair/Poor Condition:Good
Status:Posted for load [P]
Average daily traffic:1,609 [as of 2006]
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:76.6

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2018GoodGoodGoodGood160976.6
May 2017GoodGoodGoodGood160976.6
January 2016GoodGoodGoodGood160986.6
January 2014GoodGoodGoodGood160986.6
January 2012GoodGoodGoodGood160986.6
March 2010GoodGoodGoodGood160986.6
April 2008GoodGoodGoodGood160986.6
April 2006GoodGoodVery GoodVery Good100087.6

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,9081,8891900
Steel Protective Coatingsq. ft.21,94219,7482,19400
Prestressed Concrete Girder/Beamlinear ft.1,3761,3453010
Deck
Reinforced Concrete Decksq. ft.27,17424,4472,72700
Substructure
Reinforced Concrete Columneach1817010
Reinforced Concrete Abutmentlinear ft.8478600
Reinforced Concrete Pier Caplinear ft.254253100
Joints
Strip Seal Jointlinear ft.5805800
Compression Jointlinear ft.87580029
Bearings
Elastomeric Bearingeach4840800
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1,6421,6321000