Share:

US-231 over FLOOD PLAIN-OHIO RIVER

Map

Coordinates:
+37.88056, -87.01500
37°52'50" N, 87°00'54" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US-231 over FLOOD PLAIN-OHIO RIVER
Structure number:030B00160R
Location:1.1 MI. N. JCT US 60 NBL
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:95.1 ft. [29.0 m]
Total length:956.1 ft. [291.4 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:43.3 ft. [13.2 m]
Skew angle:15°
Owner:State Highway Agency [01]
Year built:1994
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:10
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: December 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:2,842 [as of 2012]
Truck traffic:31% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:89.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2017GoodVery GoodGoodVery Good284289.0
December 2015GoodVery GoodGoodVery Good284289.0
December 2013GoodVery GoodGoodVery Good289788.8
December 2011GoodVery GoodGoodVery Good294588.6
December 2009GoodVery GoodGoodVery Good312088.0
January 2008GoodVery GoodVery GoodVery Good592083.7
November 2005GoodVery GoodVery GoodVery Good521699.5

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.4,7804,780000
Deck
Reinforced Concrete Decksq. ft.41,40341,403000
Substructure
Reinforced Concrete Columneach2727000
Reinforced Concrete Abutmentlinear ft.9090000
Reinforced Concrete Pier Caplinear ft.369369000
Joints
Strip Seal Jointlinear ft.4338050
Compression Jointlinear ft.90060030
Bearings
Elastomeric Bearingeach2020000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1,9801,979010