KY-70 over GREEN RIVER & CR 1203
Map
Coordinates:
+37.19750, -86.2736137°11'51" N, 86°16'25" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | KY-70 over GREEN RIVER & CR 1203 |
Structure number: | 031B00002N |
Old structure number: | 031*0070*B0002 (from 1992 edition) |
Location: | GREEN RIVER @ BROWNSVILLE |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 288.1 ft. [87.8 m] |
Total length: | 1276.0 ft. [388.9 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 29.2 ft. [8.9 m] |
Owner: | State Highway Agency [01] |
Year built: | 1950 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 18 / H 20 [4] |
Number of main spans: | 6 |
Main spans material: | Steel continuous [4] |
Main spans design: | Girder and floorbeam system [03] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: April 2018
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 7,042 [as of 2015] |
Truck traffic: | 7% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Poor [4 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 19.7 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Estimated cost of work: | $4,673,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2018 | Poor | Satisfactory | Poor | Satisfactory | 7042 | 19.7 |
April 2016 | Poor | Satisfactory | Poor | Satisfactory | 7042 | 19.7 |
April 2014 | Poor | Satisfactory | Poor | Satisfactory | 7648 | 19.7 |
April 2012 | Fair | Satisfactory | Fair | Satisfactory | 8230 | 34.7 |
May 2010 | Fair | Satisfactory | Fair | Satisfactory | 7790 | 34.7 |
April 2008 | Fair | Satisfactory | Fair | Satisfactory | 7930 | 34.7 |
April 2006 | Fair | Satisfactory | Fair | Satisfactory | 7476 | 34.7 |
November 2003 | Fair | Satisfactory | Satisfactory | Satisfactory | 5927 | 40.5 |
August 2000 | Fair | Fair | Satisfactory | Satisfactory | 5927 | 39.5 |
July 1998 | Fair | Satisfactory | Satisfactory | Satisfactory | 5927 | 40.5 |
May 1996 | Fair | Satisfactory | Satisfactory | Satisfactory | 7757 | 40.5 |
July 1994 | Fair | Satisfactory | Good | Good | 4254 | 54.0 |
June 1992 | Fair | Satisfactory | Good | Good | 4254 | 54.0 |
April 1990 | Fair | Satisfactory | Good | Good | 4254 | 54.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 2,552 | 1,490 | 518 | 544 | 0 |
Steel Protective Coating | sq. ft. | 57,366 | 57,366 | 0 | 0 | 0 |
Steel Stringer | linear ft. | 5,104 | 2,537 | 0 | 2,567 | 0 |
Steel Protective Coating | sq. ft. | 24,880 | 24,880 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 37,256 | 35,021 | 2,235 | 0 | 0 |
Wearing Surfaces | sq. ft. | 30,627 | 30,277 | 350 | 0 | 0 |
Superstructure |
Steel Floor Beam | linear ft. | 1,682 | 482 | 1,140 | 60 | 0 |
Steel Protective Coating | sq. ft. | 11,948 | 11,948 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 16 | 12 | 0 | 4 | 0 |
Reinforced Concrete Abutment | linear ft. | 164 | 160 | 4 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 209 | 194 | 6 | 9 | 0 |
Joints |
Strip Seal Joint | linear ft. | 48 | 0 | 0 | 0 | 48 |
Pourable Joint | linear ft. | 72 | 48 | 0 | 24 | 0 |
Compression Joint | linear ft. | 24 | 24 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 18 | 0 | 18 | 0 | 0 |
Steel Protective Coating | sq. ft. | 340 | 340 | 0 | 0 | 0 |
Fixed Bearing | each | 6 | 0 | 6 | 0 | 0 |
Steel Protective Coating | sq. ft. | 266 | 266 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 2,552 | 317 | 2,135 | 100 | 0 |