KY-89 over STATION CAMP CREEK
Map
Coordinates:
+37.69250, -83.9763937°41'33" N, 83°58'35" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | KY-89 over STATION CAMP CREEK |
Structure number: | 033B00012N |
Old structure number: | 033*0089*B0012 (from 1992 edition) |
Location: | .40 MI SOU. OF JCT KY 52- |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 75.1 ft. [22.9 m] |
Total length: | 419.0 ft. [127.7 m] |
Roadway width between curbs: | 21.7 ft. [6.6 m] |
Deck width edge-to-edge: | 25.9 ft. [7.9 m] |
Owner: | State Highway Agency [01] |
Year built: | 1940 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 18 / H 20 [4] |
Number of main spans: | 2 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: May 2018
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 3,758 [as of 2014] |
Truck traffic: | 4% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 61.8 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Estimated cost of work: | $1,351,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2018 | Fair | Good | Good | Satisfactory | 3758 | 61.8 |
May 2016 | Fair | Good | Good | Satisfactory | 3758 | 63.2 |
May 2014 | Fair | Good | Good | Satisfactory | 3935 | 62.8 |
May 2012 | Fair | Good | Good | Satisfactory | 4230 | 60.2 |
May 2010 | Fair | Very Good | Satisfactory | Fair | 4060 | 47.1 |
May 2008 | Poor | Satisfactory | Serious | Fair | 3880 | 16.0 |
April 2006 | Poor | Good | Poor | Fair | 4290 | 33.0 |
April 2005 | Poor | Good | Poor | Fair | 4060 | 33.0 |
June 2004 | Fair | Good | Fair | Good | 3580 | 48.4 |
April 2000 | Fair | Good | Fair | Satisfactory | 3580 | 48.4 |
June 1998 | Fair | Satisfactory | Fair | Satisfactory | 3580 | 48.4 |
May 1996 | Fair | Good | Satisfactory | Satisfactory | 3580 | 61.7 |
April 1994 | Fair | Good | Satisfactory | Satisfactory | 926 | 64.0 |
May 1993 | Fair | Good | Satisfactory | Satisfactory | 926 | 64.0 |
April 1992 | Fair | Satisfactory | Satisfactory | Good | 926 | 64.0 |
April 1990 | Fair | Satisfactory | Satisfactory | Good | 926 | 64.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 2,080 | 2,080 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 17,420 | 17,420 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 10,859 | 10,859 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 9,077 | 9,077 | 0 | 0 | 0 |
Substructure |
Steel Column | each | 13 | 13 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1 | 1 | 0 | 0 | 0 |
Reinforced Concrete Column | each | 12 | 12 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 67 | 67 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 230 | 140 | 90 | 0 | 0 |
Joints |
Compression Joint | linear ft. | 92 | 92 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 10 | 8 | 2 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1 | 1 | 0 | 0 | 0 |
Enclosed/Concealed Bearing | each | 60 | 60 | 0 | 0 | 0 |
Fixed Bearing | each | 5 | 5 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1 | 1 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 720 | 720 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 3,600 | 3,600 | 0 | 0 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 120 | 120 | 0 | 0 | 0 |