KY-3056 over LAWRENCE CREEK
Map
Coordinates:
+38.67139, -83.8136138°40'17" N, 83°48'49" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | KY-3056 over LAWRENCE CREEK |
Structure number: | 081B00019N |
Old structure number: | 081*0435*B0019 (from 1992 edition) |
Location: | .1 MI W OF JCT KY 1597 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 29.9 ft. [9.1 m] |
Total length: | 65.9 ft. [20.1 m] |
Roadway width between curbs: | 28.9 ft. [8.8 m] |
Deck width edge-to-edge: | 36.1 ft. [11.0 m] |
Skew angle: | 30° |
Owner: | State Highway Agency [01] |
Year built: | 1947 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 18 / H 20 [4] |
Number of main spans: | 2 |
Main spans material: | Concrete [1] |
Main spans design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: November 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 696 [as of 2014] |
Truck traffic: | 3% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 85.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2017 | Fair | Fair | Fair | Fair | 696 | 85.2 |
November 2015 | Fair | Fair | Fair | Fair | 696 | 85.2 |
November 2013 | Fair | Fair | Fair | Fair | 636 | 85.3 |
November 2011 | Fair | Satisfactory | Fair | Fair | 646 | 86.3 |
November 2009 | Fair | Satisfactory | Fair | Fair | 786 | 79.8 |
December 2007 | Fair | Satisfactory | Fair | Fair | 652 | 86.3 |
November 2003 | Fair | Satisfactory | Fair | Fair | 636 | 87.3 |
February 2000 | Fair | Satisfactory | Satisfactory | Satisfactory | 687 | 99.3 |
March 1998 | Fair | Satisfactory | Satisfactory | Satisfactory | 687 | 99.3 |
December 1995 | Fair | Satisfactory | Good | Satisfactory | 480 | 99.5 |
November 1993 | Fair | Satisfactory | Good | Satisfactory | 480 | 99.5 |
November 1991 | Fair | Good | Good | Satisfactory | 480 | 99.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 396 | 383 | 9 | 4 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 2,374 | 1,020 | 1,200 | 154 | 0 |
Wearing Surfaces | sq. ft. | 1,918 | 564 | 1,200 | 154 | 0 |
Substructure |
Reinforced Concrete Column | each | 3 | 2 | 1 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 72 | 61 | 7 | 4 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 29 | 29 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 40 | 22 | 8 | 10 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 72 | 67 | 5 | 0 | 0 |