Share:

KY-933 over SPILLWAY-DOE RUN DAM

Map

Coordinates:
+37.99722, -86.11167
37°59'50" N, 86°06'42" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:KY-933 over SPILLWAY-DOE RUN DAM
Structure number:082B00005N
Old structure number:082*0933*B0005 (from 1992 edition)
Location:3.0 MI N.E. OF JCT KY 448
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:51.8 ft. [15.8 m]
Total length:220.2 ft. [67.1 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:25.9 ft. [7.9 m]
Owner:State Highway Agency [01]
Year built:1962
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: January 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:535 [as of 2013]
Truck traffic:12% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:73.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2017FairSatisfactoryGoodGood53573.7
January 2015FairSatisfactoryGoodGood53573.7
January 2014GoodGoodGoodGood52373.7
January 2012GoodGoodVery GoodGood53073.7
January 2010GoodGoodVery GoodGood53573.7
January 2008FairGoodVery GoodSatisfactory56073.7
January 2006FairGoodVery GoodSatisfactory43274.7
January 2004GoodGoodVery GoodGood58073.3
January 2002GoodGoodVery GoodGood58073.3
January 2000GoodGoodVery GoodGood58073.3
January 1998GoodGoodVery GoodGood58073.3
January 1997GoodGoodVery GoodGood58064.4
January 1996GoodGoodVery GoodGood64763.4
January 1995GoodGoodVery GoodGood64760.1
January 1994GoodGoodVery GoodGood64760.1
January 1993FairSatisfactoryVery GoodGood64760.1
January 1992GoodGoodVery GoodGood64760.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.8608362400
Deck
Reinforced Concrete Top Flangesq. ft.5,72005,72000
Wearing Surfacessq. ft.5,28005,28000
Substructure
Reinforced Concrete Columneach65100
Reinforced Concrete Abutmentlinear ft.56282800
Reinforced Concrete Pier Caplinear ft.78680100
Joints
Pourable Jointlinear ft.7875003
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.430043000