GLENN LILY ROAD over W.H. NATCHER PARKWAY
Map
Coordinates:
+37.01917, -86.5241737°01'09" N, 86°31'27" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | GLENN LILY ROAD over W.H. NATCHER PARKWAY |
Structure number: | 114B00059N |
Old structure number: | 114*9007*B0059 (from 1992 edition) |
Location: | 1 MI N OF JCT KY 3191 |
Purpose: | Carries highway over highway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 111.6 ft. [34.0 m] |
Total length: | 274.9 ft. [83.8 m] |
Roadway width between curbs: | 25.9 ft. [7.9 m] |
Deck width edge-to-edge: | 29.5 ft. [9.0 m] |
Vertical clearance below bridge: | 72.2 ft. [22.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1972 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 18 / H 20 [4] |
Number of main spans: | 3 |
Main spans material: | Steel continuous [4] |
Main spans design: | Frame [07] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 351 [as of 2016] |
Truck traffic: | 3% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Underclearances appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 65.8 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Estimated cost of work: | $935,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Fair | Satisfactory | Satisfactory | Fair | 351 | 65.8 |
August 2015 | Fair | Satisfactory | Fair | Fair | 1250 | 53.6 |
August 2013 | Good | Very Good | Good | Good | 1250 | 63.7 |
August 2011 | Fair | Fair | Good | Good | 336 | 70.8 |
August 2009 | Fair | Fair | Good | Good | 303 | 70.8 |
August 2007 | Fair | Fair | Good | Good | 357 | 70.7 |
April 2006 | Fair | Fair | Good | Good | 347 | 70.7 |
August 2003 | Fair | Satisfactory | Good | Good | 12571 | 56.6 |
October 2001 | Fair | Satisfactory | Good | Good | 12571 | 56.6 |
September 1999 | Fair | Satisfactory | Good | Good | 12571 | 57.7 |
September 1997 | Fair | Satisfactory | Good | Good | 11777 | 57.2 |
September 1995 | Fair | Satisfactory | Good | Good | 205 | 92.0 |
September 1993 | Good | Good | Good | Very Good | 205 | 92.0 |
September 1991 | Good | Good | Good | Good | 205 | 92.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,100 | 1,060 | 36 | 4 | 0 |
Steel Protective Coating | sq. ft. | 9,534 | 9,534 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 8,113 | 7,970 | 143 | 0 | 0 |
Wearing Surfaces | sq. ft. | 7,133 | 7,062 | 71 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 59 | 0 | 44 | 15 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 52 | 0 | 52 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 59 | 0 | 59 | 0 | 0 |
Bearings |
Movable Bearing | each | 8 | 0 | 8 | 0 | 0 |
Steel Protective Coating | sq. ft. | 32 | 32 | 0 | 0 | 0 |
Fixed Bearing | each | 8 | 8 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 32 | 32 | 0 | 0 | 0 |
Bridge Rail |