LA0182 over CHARENTON
Map
Coordinates:
+29.82700, -91.5412029°49'37" N, 91°32'28" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | LA0182 over CHARENTON |
Structure number: | 035100040609371 |
Location: | 2,4 MI NORTH OF LA 3211 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 299.9 ft. [91.4 m] |
Total length: | 2422.0 ft. [738.2 m] |
Roadway width between curbs: | 24.3 ft. [7.4 m] |
Deck width edge-to-edge: | 26.9 ft. [8.2 m] |
Vertical clearance above deck: | 15.1 ft. [4.6 m] |
Vertical clearance below bridge: | 49.2 ft. [15.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1941 |
Historic significance: | Bridge is eligible for the National Register of Historic Places [2] |
Design load: | M 13.5 / H 15 [2] |
Main span material: | Steel [3] |
Main span design: | Truss - Thru [10] |
Deck type: | Concrete Cast-in-Place [1] |
Latest Available Inspection: March 2018
Good/Fair/Poor Condition: | Poor |
Status: | Posted for load [P] |
Average daily traffic: | 7,000 [as of 2016] |
Truck traffic: | 9% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Poor [4 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Basically intolerable requiring high priority of replacement [2] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 17.4 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $9,445,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2018 | Poor | Satisfactory | Poor | Satisfactory | 7000 | 17.4 |
March 2016 | Poor | Satisfactory | Poor | Satisfactory | 7000 | 17.4 |
March 2014 | Poor | Satisfactory | Poor | Satisfactory | 7000 | 17.0 |
February 2012 | Fair | Satisfactory | Fair | Satisfactory | 6200 | 38.9 |
March 2011 | Fair | Satisfactory | Fair | Satisfactory | 6900 | 38.3 |
March 2010 | Fair | Satisfactory | Fair | Satisfactory | 7000 | 38.2 |
February 2009 | Fair | Satisfactory | Fair | Satisfactory | 7100 | 38.1 |
March 2008 | Fair | Satisfactory | Fair | Satisfactory | 8100 | 37.3 |
January 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 8100 | 49.0 |
March 2006 | Fair | Satisfactory | Satisfactory | Satisfactory | 8100 | 49.0 |
May 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 8100 | 49.0 |
February 2003 | Fair | Satisfactory | Satisfactory | Satisfactory | 7900 | 49.2 |
March 2001 | Fair | Satisfactory | Satisfactory | Satisfactory | 8123 | 49.0 |
March 1998 | Fair | Satisfactory | Satisfactory | Satisfactory | 7865 | 49.2 |
March 1996 | Fair | Satisfactory | Satisfactory | Satisfactory | 7865 | 56.7 |
January 1994 | Fair | Satisfactory | Satisfactory | Satisfactory | 6515 | 57.2 |
February 1993 | Fair | Satisfactory | Satisfactory | Satisfactory | 6971 | 56.9 |
March 1992 | Fair | Satisfactory | Satisfactory | Satisfactory | 6971 | 56.9 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 10,650 | 10,168 | 426 | 56 | 0 |
Steel Stringer | linear ft. | 3,636 | 0 | 3,352 | 280 | 4 |
Steel Protective Coating | sq. ft. | 19,544 | 0 | 0 | 19,544 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 58,416 | 0 | 56,963 | 1,453 | 0 |
Superstructure |
Steel Truss | linear ft. | 604 | 2 | 357 | 233 | 12 |
Steel Protective Coating | sq. ft. | 100 | 0 | 0 | 100 | 0 |
Steel Floor Beam | linear ft. | 297 | 0 | 190 | 106 | 1 |
Steel Protective Coating | sq. ft. | 2,438 | 0 | 0 | 2,438 | 0 |
Substructure |
Reinforced Concrete Column | each | 104 | 100 | 4 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 90 | 90 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 1,377 | 1,374 | 3 | 0 | 0 |
Joints |
Open Joint | linear ft. | 1,310 | 1,162 | 124 | 0 | 24 |
Assembly without Seal Joint | linear ft. | 80 | 32 | 0 | 48 | 0 |
Bearings |
Movable Bearing | each | 520 | 0 | 238 | 282 | 0 |
Steel Protective Coating | sq. ft. | 1,083 | 0 | 10 | 0 | 1,073 |
Enclosed/Concealed Bearing | each | 4 | 0 | 0 | 4 | 0 |
Steel Protective Coating | sq. ft. | 134 | 0 | 67 | 67 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 608 | 0 | 546 | 62 | 0 |
Steel Protective Coating | sq. ft. | 1,216 | 0 | 0 | 1,216 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 4,260 | 4,253 | 1 | 6 | 0 |