ST 2 A/MASS AVE over COMB STRW DR & CHAS RIV
Map
Coordinates:
+42.35439, -71.0912042°21'16" N, 71°05'28" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | ST 2 A/MASS AVE over COMB STRW DR & CHAS RIV |
Structure number: | B160124EYDOTNBI |
Location: | .8 MI E OF BU BRIDGE |
Purpose: | Carries highway and pedestrian walkway over highway and waterway |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 105.3 ft. [32.1 m] |
Total length: | 2171.4 ft. [661.8 m] |
Roadway width between curbs: | 51.8 ft. [15.8 m] |
Deck width edge-to-edge: | 74.2 ft. [22.6 m] |
Vertical clearance below bridge: | 9.8 ft. [3.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1891 |
Year reconstructed: | 1990 |
Historic significance: | Bridge is on the National Register of Historic Places [1] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 25 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: May 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 38,000 [as of 2017] |
Truck traffic: | 8% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Underclearances appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 64.8 |
Recommended work: | Widening of existing bridge or other major structure without deck rehabilitation or replacement [33] |
Estimated cost of work: | $51,857,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2017 | Good | Good | Good | Good | 38000 | 64.8 |
May 2015 | Good | Good | Good | Good | 27500 | 68.7 |
May 2013 | Good | Good | Good | Good | 28433 | 68.4 |
May 2011 | Good | Good | Good | Good | 49000 | 64.0 |
May 2009 | Good | Good | Very Good | Good | 49000 | 64.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 12,986 | 12,906 | 80 | 0 | 0 |
Steel Protective Coating | sq. ft. | 190,293 | 189,543 | 300 | 250 | 200 |
Steel Stringer | linear ft. | 4,302 | 4,302 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 18,056 | 18,056 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 118,334 | 116,968 | 1,183 | 183 | 0 |
Wearing Surfaces | sq. ft. | 112,906 | 112,862 | 36 | 8 | 0 |
Superstructure |
Steel Floor Beam | linear ft. | 56 | 50 | 6 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1,280 | 1,263 | 2 | 5 | 10 |
Substructure |
Reinforced Concrete Column | each | 2 | 2 | 0 | 0 | 0 |
Masonry Pier Wall | linear ft. | 1,711 | 1,706 | 5 | 0 | 0 |
Masonry Abutment | linear ft. | 155 | 77 | 78 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 145 | 140 | 0 | 0 | 5 |
Assembly with Seal | each | 297 | 297 | 0 | 0 | 0 |
Open Joint | linear ft. | 134 | 134 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 150 | 73 | 58 | 19 | 0 |
Steel Protective Coating | sq. ft. | 450 | 315 | 45 | 45 | 45 |
Fixed Bearing | each | 26 | 23 | 3 | 0 | 0 |
Steel Protective Coating | sq. ft. | 78 | 78 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 8,657 | 8,188 | 463 | 6 | 0 |
Steel Protective Coating | sq. ft. | 12,992 | 9,095 | 974 | 2,923 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 4,329 | 3,462 | 649 | 216 | 2 |