HWY BLAKEMORE ST over RR AMTRAK/MBTA
Map
Coordinates:
+42.28549, -71.1195542°17'08" N, 71°07'10" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | HWY BLAKEMORE ST over RR AMTRAK/MBTA |
Structure number: | B16105390MUNNBI |
Location: | 3.8 W OF RT 93 |
Purpose: | Carries highway and pedestrian walkway over railroad |
Route classification: | Local (Urban) [19] |
Length of largest span: | 70.9 ft. [21.6 m] |
Total length: | 75.1 ft. [22.9 m] |
Roadway width between curbs: | 22.0 ft. [6.7 m] |
Deck width edge-to-edge: | 41.0 ft. [12.5 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1882 |
Year reconstructed: | 1950 |
Historic significance: | Historical significance is not determinable at this time [4] |
Main span material: | Steel [3] |
Main span design: | Girder and floorbeam system [03] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: March 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 13,200 [as of 2017] |
Truck traffic: | 5% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Underclearances appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Roadway alignment appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 58.9 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $1,490,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2017 | Fair | Satisfactory | Fair | Good | 13200 | 58.9 |
March 2015 | Fair | Satisfactory | Satisfactory | Good | 9900 | 70.7 |
March 2013 | Fair | Satisfactory | Satisfactory | Good | 9900 | 70.7 |
March 2011 | Fair | Satisfactory | Satisfactory | Good | 9900 | 70.7 |
March 2009 | Fair | Satisfactory | Satisfactory | Good | 9900 | 70.7 |
March 2007 | Fair | Satisfactory | Satisfactory | Good | 9600 | 70.7 |
March 2005 | Fair | Satisfactory | Satisfactory | Good | 9400 | 70.8 |
November 2002 | Fair | Satisfactory | Satisfactory | Good | 13100 | 70.3 |
December 2000 | Fair | Satisfactory | Satisfactory | Good | 11200 | 70.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 144 | 0 | 66 | 72 | 6 |
Steel Protective Coating | sq. ft. | 1,008 | 0 | 1,008 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 1,947 | 1,837 | 110 | 0 | 0 |
Wearing Surfaces | sq. ft. | 1,653 | 827 | 826 | 0 | 0 |
Superstructure |
Steel Floor Beam | linear ft. | 776 | 0 | 776 | 0 | 0 |
Steel Protective Coating | sq. ft. | 3,876 | 0 | 3,876 | 0 | 0 |
Substructure |
Masonry Abutment | linear ft. | 82 | 0 | 82 | 0 | 0 |
Bearings |
Movable Bearing | each | 2 | 0 | 2 | 0 | 0 |
Steel Protective Coating | sq. ft. | 4 | 0 | 4 | 0 | 0 |
Fixed Bearing | each | 2 | 0 | 2 | 0 | 0 |
Steel Protective Coating | sq. ft. | 4 | 0 | 4 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 150 | 0 | 150 | 0 | 0 |
Steel Protective Coating | sq. ft. | 600 | 0 | 600 | 0 | 0 |