HWY LAND BLVD over WATER LECHMERE CANAL
Map
Coordinates:
+42.36845, -71.0740442°22'06" N, 71°04'27" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | HWY LAND BLVD over WATER LECHMERE CANAL |
Structure number: | C010013F1DOTNBI |
Old structure number: | 443812022101 (from 1992 edition) |
Location: | 500 FT W OF JCT SR 28 |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 44.0 ft. [13.4 m] |
Total length: | 130.9 ft. [39.9 m] |
Roadway width between curbs: | 44.9 ft. [13.7 m] |
Deck width edge-to-edge: | 60.7 ft. [18.5 m] |
Vertical clearance below bridge: | 6.6 ft. [2.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1986 |
Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: March 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 53,793 [as of 2018] |
Truck traffic: | 4% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | In place and functioning [2] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 70.4 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Estimated cost of work: | $10,666,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2018 | Fair | Fair | Good | Good | 53793 | 70.4 |
March 2016 | Fair | Satisfactory | Good | Good | 56800 | 71.1 |
March 2014 | Fair | Satisfactory | Good | Good | 40500 | 73.1 |
March 2012 | Fair | Satisfactory | Good | Good | 40500 | 73.1 |
March 2010 | Good | Good | Good | Good | 40300 | 73.1 |
April 1998 | Good | Very Good | Very Good | Very Good | 25600 | 77.9 |
April 1994 | Good | Very Good | Very Good | Very Good | 36500 | 69.4 |
April 1992 | Good | Very Good | Very Good | Very Good | 34800 | 49.8 |
June 1990 | Good | Very Good | Very Good | Very Good | 68901 | 44.4 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,960 | 1,600 | 360 | 0 | 0 |
Steel Protective Coating | sq. ft. | 11,995 | 9,767 | 0 | 0 | 2,228 |
Deck |
Reinforced Concrete Deck | sq. ft. | 14,548 | 13,479 | 143 | 926 | 0 |
Wearing Surfaces | sq. ft. | 10,714 | 7,487 | 3,225 | 2 | 0 |
Substructure |
Reinforced Concrete Column | each | 14 | 0 | 14 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 104 | 98 | 6 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 2,778 | 0 | 0 | 2,778 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 234 | 234 | 0 | 0 | 0 |
Joints |
Compression Joint | linear ft. | 92 | 0 | 92 | 0 | 0 |
Bearings |
Movable Bearing | each | 45 | 43 | 0 | 2 | 0 |
Steel Protective Coating | sq. ft. | 1,472 | 0 | 0 | 1,472 | 0 |
Fixed Bearing | each | 15 | 15 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 490 | 0 | 490 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 261 | 261 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 963 | 963 | 0 | 0 | 0 |