US 5 /ST10/GRNFLD over WATER DEERFIELD RIVER
Map
Coordinates:
+42.56958, -72.5920342°34'10" N, 72°35'31" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 5 /ST10/GRNFLD over WATER DEERFIELD RIVER |
Structure number: | D060020U4DOTNBI |
Old structure number: | 0U4003213000101 (from 1992 edition) |
Location: | AT JCT RIVER RD. |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 132.9 ft. [40.5 m] |
Total length: | 538.1 ft. [164.0 m] |
Roadway width between curbs: | 40.0 ft. [12.2 m] |
Deck width edge-to-edge: | 50.2 ft. [15.3 m] |
Skew angle: | 33° |
Owner: | State Highway Agency [01] |
Year built: | 1932 |
Year reconstructed: | 1991 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 18 / H 20 [4] |
Number of main spans: | 3 |
Main spans material: | Steel [3] |
Main spans design: | Truss - Deck [09] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: May 2017
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 17,850 [as of 2017] |
Truck traffic: | 10% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Serious [3 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4] |
Sufficiency rating: | 33.8 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $19,604,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2017 | Poor | Fair | Serious | Fair | 17850 | 33.8 |
May 2015 | Poor | Fair | Poor | Poor | 9700 | 53.2 |
May 2013 | Poor | Fair | Poor | Poor | 9700 | 53.2 |
May 2011 | Poor | Satisfactory | Fair | Poor | 9700 | 54.4 |
May 2009 | Poor | Satisfactory | Fair | Poor | 9700 | 54.4 |
May 1999 | Good | Good | Good | Good | 6400 | 93.7 |
May 1997 | Good | Good | Good | Good | 6400 | 93.7 |
May 1995 | Good | Very Good | Very Good | Very Good | 6400 | 82.5 |
July 1991 | Good | Very Good | Very Good | Good | 30731 | 57.3 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,035 | 899 | 46 | 90 | 0 |
Steel Protective Coating | sq. ft. | 8,487 | 0 | 8,054 | 433 | 0 |
Steel Stringer | linear ft. | 2,502 | 2,222 | 276 | 4 | 0 |
Steel Protective Coating | sq. ft. | 9,189 | 0 | 8,900 | 281 | 8 |
Deck |
Reinforced Concrete Deck | sq. ft. | 27,166 | 24,746 | 2,420 | 0 | 0 |
Wearing Surfaces | sq. ft. | 21,458 | 5,080 | 11,309 | 5,069 | 0 |
Superstructure |
Steel Truss | linear ft. | 1,600 | 975 | 530 | 89 | 6 |
Steel Protective Coating | sq. ft. | 32,000 | 0 | 18,228 | 13,752 | 20 |
Steel Floor Beam | linear ft. | 2,163 | 1,777 | 242 | 59 | 85 |
Steel Protective Coating | sq. ft. | 9,702 | 0 | 5,673 | 3,944 | 85 |
Steel Gusset Plate | each | 736 | 494 | 179 | 36 | 27 |
Substructure |
Reinforced Concrete Column | each | 10 | 8 | 2 | 0 | 0 |
Reinforced Concrete Pier Wall | linear ft. | 269 | 240 | 13 | 16 | 0 |
Reinforced Concrete Abutment | linear ft. | 118 | 22 | 56 | 40 | 0 |
Joints |
Strip Seal Joint | linear ft. | 142 | 0 | 0 | 142 | 0 |
Bearings |
Elastomeric Bearing | each | 64 | 50 | 14 | 0 | 0 |
Steel Protective Coating | sq. ft. | 128 | 128 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 992 | 964 | 3 | 25 | 0 |