Share:

US 1 CONN RPS A&B over I 95 /ST128

Map

Coordinates:
+42.51955, -70.99364
42°31'10" N, 70°59'37" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 1 CONN RPS A&B over I 95 /ST128
Structure number:P030232VNDOTNBI
Location:.2 MI E US1
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:86.0 ft. [26.2 m]
Total length:243.1 ft. [74.1 m]
Roadway width between curbs:71.9 ft. [21.9 m]
Deck width edge-to-edge:77.1 ft. [23.5 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:20°
Owner:State Highway Agency [01]
Year built:1959
Year reconstructed:2010
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:4
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:59,400 [as of 2017]
Truck traffic:7% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:74.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2017FairGoodGoodFair5940074.0
May 2015FairGoodGoodSatisfactory5940079.3
May 2013PoorGoodPoorSatisfactory5940048.5
May 2011FairGoodGoodSatisfactory5940079.3
May 2009FairSatisfactorySatisfactoryGood5940078.3

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2,8812,40148000
Steel Protective Coatingsq. ft.23,95323,953000
Deck
Reinforced Concrete Decksq. ft.18,51818,03848000
Wearing Surfacessq. ft.17,16017,01814200
Substructure
Reinforced Concrete Columneach1501410
Reinforced Concrete Abutmentlinear ft.1651362630
Reinforced Concrete Pier Caplinear ft.2400216240
Joints
Pourable Jointlinear ft.23217248120
Bearings
Movable Bearingeach4848000
Steel Protective Coatingsq. ft.9696000
Fixed Bearingeach4848000
Steel Protective Coatingsq. ft.9696000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.720450225450