Share:

TROY ROAD over 25 MILE STREAM

Map

Coordinates:
+44.68926, -69.41795
44°41'21" N, 69°25'05" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:TROY ROAD over 25 MILE STREAM
Structure number:5144
Location:0.6 MI E OF RTE 11 & 100
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:35.1 ft. [10.7 m]
Total length:76.1 ft. [23.2 m]
Roadway width between curbs:20.0 ft. [6.1 m]
Deck width edge-to-edge:23.0 ft. [7.0 m]
Owner:State Highway Agency [01]
Year built:1921
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: July 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,263 [as of 2016]
Truck traffic:5% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank and embankment protection is severely undermined. River control devices have severe damage. Large deposits of debris are in the channel. [4]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:62.3

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2018FairFairFairFair126362.3
December 2016FairFairFairFair122462.4
May 2015FairFairFairFair120267.4
November 2014FairFairFairFair108068.1
December 2012FairFairFairFair108168.1
September 2011FairFairFairFair109068.1
April 2010FairFairFairFair82568.3
November 2009FairFairFairFair82368.3
December 2008FairFairFairFair88468.3
March 2007FairFairFairFair89067.3
August 2004FairFairSatisfactoryFair128566.0
July 2002FairFairSatisfactoryFair124865.0
June 2000FairFairSatisfactoryFair121265.0
June 1998FairSatisfactorySatisfactoryFair118066.1
November 1996FairSatisfactoryFairFair113265.1
January 1995FairSatisfactoryFairSatisfactory109665.1
December 1992FairSatisfactoryGoodSatisfactory105176.3
June 1990FairSatisfactoryGoodSatisfactory106974.6

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.3800300800
Deck
Reinforced Concrete Top Flangesq. ft.1,74801,5981500
Substructure
Reinforced Concrete Pier Walllinear ft.23012110
Reinforced Concrete Abutmentlinear ft.46422200
Joints
Pourable Jointlinear ft.2302300
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.152152000