OSSINEKE ROAD over DEVILS RIVER
Map
Coordinates:
+44.91759, -83.4329744°55'03" N, 83°25'59" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | OSSINEKE ROAD over DEVILS RIVER |
Structure number: | 000000000000355 |
Old structure number: | 04306A00022B010 (from 1992 edition) |
Location: | OSSINEKE |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 26.9 ft. [8.2 m] |
Total length: | 30.8 ft. [9.4 m] |
Roadway width between curbs: | 22.0 ft. [6.7 m] |
Deck width edge-to-edge: | 22.0 ft. [6.7 m] |
Owner: | County Highway Agency [02] |
Year built: | 1964 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Poor |
Status: | Posted for load [P] |
Average daily traffic: | 800 [as of 2010] |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Poor [4 out of 9] |
Substructure condition: | Poor [4 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
Sufficiency rating: | 41.3 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $630,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Poor | Fair | Poor | Poor | 800 | 41.3 |
August 2017 | Poor | Fair | Poor | Poor | 800 | 41.3 |
August 2016 | Poor | Fair | Poor | Poor | 800 | 41.3 |
August 2014 | Poor | Fair | Poor | Poor | 800 | 29.8 |
August 2012 | Poor | Fair | Poor | Poor | 800 | 29.8 |
August 2010 | Poor | Fair | Poor | Poor | 800 | 31.3 |
July 2008 | Poor | Fair | Poor | Poor | 800 | 31.3 |
August 2006 | Poor | Fair | Poor | Poor | 800 | 31.5 |
May 2004 | Poor | Fair | Poor | Poor | 800 | 31.5 |
September 2002 | Fair | Fair | Fair | Fair | 650 | 48.5 |
September 2000 | Fair | Fair | Fair | Fair | 650 | 48.5 |
September 1998 | Fair | Fair | Fair | Fair | 650 | 48.5 |
May 1997 | Poor | Poor | Fair | Fair | 650 | 46.5 |
June 1995 | Poor | Fair | Poor | Fair | 550 | 31.4 |
June 1993 | Poor | Fair | Poor | Fair | 550 | 31.4 |
September 1991 | Poor | Fair | Poor | Fair | 550 | 29.3 |