ARENAC STATE ROAD over PINE RIVER
Map
Coordinates:
+43.98522, -83.8876443°59'07" N, 83°53'16" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | ARENAC STATE ROAD over PINE RIVER |
Structure number: | 000000000000444 |
Old structure number: | 06200042000B010 (from 1992 edition) |
Location: | 3 MILES EAST OF STANDISH |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 45.9 ft. [14.0 m] |
Total length: | 100.4 ft. [30.6 m] |
Roadway width between curbs: | 30.5 ft. [9.3 m] |
Deck width edge-to-edge: | 33.1 ft. [10.1 m] |
Skew angle: | 15° |
Owner: | County Highway Agency [02] |
Year built: | 1940 |
Year reconstructed: | 2013 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 2 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,200 [as of 2010] |
Truck traffic: | 10% of total traffic |
Deck condition: | Very Good [8 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 96.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Good | Very Good | Very Good | Good | 1200 | 96.2 |
August 2016 | Good | Very Good | Very Good | Good | 1200 | 96.2 |
August 2014 | Good | Excellent | Very Good | Good | 1200 | 90.2 |
August 2012 | Fair | Fair | Satisfactory | Good | 1200 | 88.2 |
August 2010 | Fair | Fair | Satisfactory | Good | 1824 | 74.4 |
August 2008 | Fair | Fair | Satisfactory | Good | 1824 | 74.4 |
May 2006 | Fair | Fair | Satisfactory | Good | 1824 | 74.4 |
November 2004 | Fair | Satisfactory | Satisfactory | Good | 1824 | 75.4 |
November 2002 | Fair | Satisfactory | Good | Good | 1824 | 76.4 |
December 2000 | Fair | Satisfactory | Good | Good | 1824 | 76.4 |
June 1998 | Fair | Satisfactory | Good | Good | 1824 | 76.4 |
August 1996 | Poor | Poor | Satisfactory | Satisfactory | 430 | 74.9 |
March 1994 | Poor | Poor | Satisfactory | Satisfactory | 430 | 78.2 |
April 1992 | Poor | Poor | Satisfactory | Satisfactory | 430 | 78.2 |
January 1990 | Poor | Poor | Satisfactory | Satisfactory | 430 | 78.2 |