COURT STREET over AUGRES RIVER
Map
Coordinates:
+44.10871, -83.6961844°06'31" N, 83°41'46" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | COURT STREET over AUGRES RIVER |
Structure number: | 000000000000475 |
Old structure number: | 06311H00019B010 (from 1992 edition) |
Location: | 0.2 MI S OF TWINING |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 89.9 ft. [27.4 m] |
Total length: | 94.8 ft. [28.9 m] |
Roadway width between curbs: | 20.0 ft. [6.1 m] |
Deck width edge-to-edge: | 26.9 ft. [8.2 m] |
Skew angle: | 30° |
Owner: | County Highway Agency [02] |
Year built: | 1925 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Main span material: | Concrete [1] |
Main span design: | Girder and floorbeam system [03] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 145 [as of 1998] |
Deck condition: | Poor [4 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
Sufficiency rating: | 66.9 |
Estimated cost of work: | $6,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Poor | Poor | Fair | Fair | 145 | 66.9 |
August 2017 | Poor | Poor | Poor | Fair | 145 | 50.9 |
August 2016 | Poor | Poor | Poor | Fair | 145 | 50.9 |
August 2014 | Fair | Fair | Satisfactory | Satisfactory | 145 | 63.2 |
August 2012 | Fair | Fair | Satisfactory | Satisfactory | 145 | 63.2 |
August 2010 | Fair | Fair | Satisfactory | Satisfactory | 145 | 63.2 |
October 2008 | Fair | Fair | Satisfactory | Satisfactory | 145 | 63.2 |
October 2006 | Fair | Fair | Satisfactory | Satisfactory | 145 | 62.2 |
November 2004 | Fair | Fair | Good | Good | 145 | 62.2 |
November 2002 | Fair | Satisfactory | Satisfactory | Good | 145 | 63.2 |
December 2000 | Good | Good | Good | Good | 145 | 63.2 |
June 1998 | Good | Good | Good | Good | 145 | 64.7 |
August 1996 | Poor | Poor | Satisfactory | Satisfactory | 90 | 71.2 |
March 1994 | Poor | Poor | Satisfactory | Satisfactory | 90 | 74.5 |
April 1992 | Poor | Poor | Satisfactory | Satisfactory | 90 | 74.5 |
January 1990 | Poor | Poor | Satisfactory | Satisfactory | 90 | 74.5 |