US-12 over GALIEN RIVER
Map
Coordinates:
+41.79905, -86.6894641°47'57" N, 86°41'22" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US-12 over GALIEN RIVER |
Structure number: | 000000000000856 |
Old structure number: | 11111021000B010 (from 1992 edition) |
Location: | 3.0 MI E OF NEW BUFFALO |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 43.0 ft. [13.1 m] |
Total length: | 128.9 ft. [39.3 m] |
Roadway width between curbs: | 43.6 ft. [13.3 m] |
Deck width edge-to-edge: | 46.9 ft. [14.3 m] |
Owner: | State Highway Agency [01] |
Year built: | 1953 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 6,125 [as of 2018] |
Truck traffic: | 11% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 86.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Fair | Satisfactory | Fair | Satisfactory | 6125 | 86.0 |
July 2016 | Fair | Satisfactory | Fair | Satisfactory | 6988 | 85.7 |
July 2014 | Fair | Satisfactory | Fair | Satisfactory | 6988 | 85.7 |
July 2012 | Fair | Satisfactory | Fair | Satisfactory | 6988 | 85.7 |
July 2010 | Fair | Satisfactory | Fair | Satisfactory | 6988 | 85.7 |
November 2008 | Fair | Satisfactory | Fair | Satisfactory | 6988 | 85.7 |
July 2006 | Poor | Satisfactory | Serious | Fair | 6687 | 45.4 |
July 2004 | Fair | Satisfactory | Fair | Fair | 6200 | 80.8 |
July 2002 | Fair | Satisfactory | Good | Satisfactory | 6200 | 78.8 |
August 2000 | Fair | Satisfactory | Very Good | Good | 6200 | 78.8 |
July 1998 | Fair | Satisfactory | Very Good | Good | 6200 | 75.8 |
June 1996 | Good | Good | Very Good | Good | 6200 | 73.8 |
May 1994 | Good | Good | Very Good | Good | 5600 | 73.8 |
December 1993 | Fair | Good | Very Good | Satisfactory | 5600 | 73.8 |
July 1991 | Poor | Good | Poor | Satisfactory | 5600 | 48.3 |
April 1991 | Fair | Good | Good | Satisfactory | 5600 | 73.8 |