US-31 NB over ST JOSEPH RIVER
Map
Coordinates:
+41.98633, -86.3705441°59'11" N, 86°22'14" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US-31 NB over ST JOSEPH RIVER |
Structure number: | 000000000012752 |
Old structure number: | 11111112000B010 (from 1992 edition) |
Location: | 1.5 MI N OF OLD US-31 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 118.4 ft. [36.1 m] |
Total length: | 904.2 ft. [275.6 m] |
Roadway width between curbs: | 44.0 ft. [13.4 m] |
Deck width edge-to-edge: | 47.2 ft. [14.4 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Skew angle: | 20° |
Owner: | State Highway Agency [01] |
Year built: | 1998 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 22.5 / HS 25 [9] |
Number of main spans: | 8 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: July 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 5,465 [as of 2007] |
Truck traffic: | 16% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 88.7 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
July 2018 | Fair | Satisfactory | Fair | Good | 5465 | 88.7 |
August 2016 | Good | Good | Good | Good | 5465 | 99.7 |
August 2014 | Good | Good | Good | Good | 5465 | 99.7 |
August 2012 | Good | Good | Good | Good | 5465 | 99.7 |
August 2010 | Good | Good | Good | Good | 5465 | 99.7 |
August 2008 | Good | Very Good | Good | Good | 5465 | 99.7 |
August 2006 | Good | Very Good | Good | Good | 5045 | 99.8 |
August 2004 | Fair | Very Good | Very Good | Satisfactory | 11000 | 100.0 |
October 2002 | Good | Excellent | Excellent | Excellent | 11000 | 100.0 |
May 2001 | Good | Excellent | Excellent | Excellent | 11000 | 100.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 5,423 | 5,407 | 14 | 2 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 42,714 | 42,378 | 326 | 10 | 0 |
Substructure |
Reinforced Concrete Column | each | 14 | 14 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 112 | 111 | 1 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 352 | 346 | 6 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 150 | 16 | 134 | 0 | 0 |
Pourable Joint | linear ft. | 94 | 0 | 94 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 96 | 96 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 1,808 | 1,746 | 18 | 44 | 0 |
Steel Protective Coating | sq. ft. | 5,737 | 0 | 5,734 | 0 | 3 |