Share:

I-194 over FOUNTAIN STREET

Map

Coordinates:
+42.31439, -85.18087
42°18'52" N, 85°10'51" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-194 over FOUNTAIN STREET
Structure number:000000000001210
Old structure number:13113033000S090 (from 1992 edition)
Location:3.3 MI N OF I-94
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:71.9 ft. [21.9 m]
Total length:138.8 ft. [42.3 m]
Roadway width between curbs:85.0 ft. [25.9 m]
Deck width edge-to-edge:92.2 ft. [28.1 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:10°
Owner:State Highway Agency [01]
Year built:1966
Year reconstructed:2013
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: September 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:21,000 [as of 2013]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:78.4

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2017FairSatisfactoryFairGood2100078.4
September 2015FairSatisfactoryFairGood2100078.4
September 2013FairSatisfactoryFairGood2100078.4
September 2011PoorFairPoorSatisfactory2119060.0
September 2009PoorFairPoorSatisfactory2119060.0
September 2007PoorSatisfactoryPoorSatisfactory1940061.5
September 2005FairSatisfactoryFairSatisfactory1940083.9
September 2003FairFairFairSatisfactory2000082.7
September 2001FairFairSatisfactorySatisfactory2000094.2
October 1999PoorFairSatisfactoryPoor2000065.8
September 1997FairFairGoodSatisfactory2000094.2
June 1995FairFairGoodSatisfactory1020095.5
May 1993FairFairGoodSatisfactory1020095.5
May 1991FairSatisfactoryGoodSatisfactory1020096.5

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,7711,7556100
Steel Protective Coatingsq. ft.14,52314,522100
Deck
Reinforced Concrete Decksq. ft.12,78912,528195660
Superstructure
Steel Pin or Pin & Hangar Assemblyeach2626000
Substructure
Reinforced Concrete Columneach1414000
Concrete Protective Coatingsq. ft.1,3201,320000
Reinforced Concrete Abutmentlinear ft.1871642210
Concrete Protective Coatingsq. ft.539539000
Reinforced Concrete Pier Caplinear ft.188178820
Concrete Protective Coatingsq. ft.2,2822,282000
Joints
Strip Seal Jointlinear ft.1822415800
Pourable Jointlinear ft.2121585400
Bearings
Movable Bearingeach2626000
Steel Protective Coatingsq. ft.104104000
Fixed Bearingeach26115100
Steel Protective Coatingsq. ft.5250200
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.5555193600