I-94 WB over 9 MILE ROAD
Map
Coordinates:
+42.28734, -85.1204742°17'14" N, 85°07'14" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I-94 WB over 9 MILE ROAD |
Structure number: | 000000000001266 |
Old structure number: | 13113082000S034 (from 1992 edition) |
Location: | 3.2 MI E OF M-66 |
Purpose: | Carries highway over highway |
Route classification: | Principal Arterial - Interstate (Urban) [11] |
Length of largest span: | 44.3 ft. [13.5 m] |
Total length: | 117.1 ft. [35.7 m] |
Roadway width between curbs: | 42.0 ft. [12.8 m] |
Deck width edge-to-edge: | 47.2 ft. [14.4 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Skew angle: | 18° |
Owner: | State Highway Agency [01] |
Year built: | 1959 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Concrete [1] |
Main spans design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 22,400 [as of 2010] |
Truck traffic: | 23% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Equal to present desirable criteria [8] |
Underclearances appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 94.9 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Fair | Satisfactory | Satisfactory | Satisfactory | 22400 | 94.9 |
August 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 22400 | 94.9 |
August 2013 | Fair | Satisfactory | Satisfactory | Satisfactory | 22400 | 94.9 |
August 2011 | Fair | Satisfactory | Satisfactory | Satisfactory | 22400 | 94.9 |
August 2009 | Fair | Satisfactory | Satisfactory | Satisfactory | 22030 | 94.9 |
August 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 23904 | 94.7 |
August 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 23904 | 94.7 |
August 2003 | Fair | Satisfactory | Satisfactory | Good | 18500 | 95.2 |
August 2001 | Fair | Good | Satisfactory | Good | 18500 | 95.2 |
August 1999 | Fair | Good | Satisfactory | Good | 18500 | 95.2 |
August 1997 | Fair | Good | Satisfactory | Good | 18500 | 95.2 |
July 1995 | Fair | Good | Satisfactory | Good | 17100 | 95.7 |
April 1993 | Good | Good | Good | Good | 17100 | 95.7 |
April 1991 | Good | Good | Good | Good | 17100 | 95.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 1,056 | 955 | 100 | 1 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 5,555 | 5,413 | 85 | 57 | 0 |
Wearing Surfaces | sq. ft. | 4,941 | 4,773 | 82 | 86 | 0 |
Substructure |
Reinforced Concrete Column | each | 8 | 0 | 1 | 7 | 0 |
Reinforced Concrete Abutment | linear ft. | 116 | 105 | 5 | 6 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 98 | 0 | 77 | 21 | 0 |
Joints |
Strip Seal Joint | linear ft. | 88 | 42 | 46 | 0 | 0 |
Pourable Joint | linear ft. | 88 | 0 | 44 | 44 | 0 |
Bearings |
Movable Bearing | each | 27 | 0 | 0 | 27 | 0 |
Steel Protective Coating | sq. ft. | 27 | 0 | 0 | 0 | 27 |
Fixed Bearing | each | 9 | 0 | 0 | 9 | 0 |
Steel Protective Coating | sq. ft. | 9 | 0 | 0 | 0 | 9 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 234 | 10 | 211 | 13 | 0 |