US-131 over BOYNE RIVER
Map
Coordinates:
+45.18021, -84.9142745°10'49" N, 84°54'51" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US-131 over BOYNE RIVER |
Structure number: | 000000000001479 |
Old structure number: | 15115091000B010 (from 1992 edition) |
Location: | 0.8 MI N OF BOYNE FALLS |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 31.8 ft. [9.7 m] |
Total length: | 31.8 ft. [9.7 m] |
Roadway width between curbs: | 38.1 ft. [11.6 m] |
Deck width edge-to-edge: | 43.6 ft. [13.3 m] |
Skew angle: | 22° |
Owner: | State Highway Agency [01] |
Year built: | 1947 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 6,736 [as of 2007] |
Truck traffic: | 8% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 83.5 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Fair | Good | Very Good | Satisfactory | 6736 | 83.5 |
August 2015 | Fair | Good | Very Good | Satisfactory | 6736 | 83.5 |
August 2013 | Fair | Good | Very Good | Satisfactory | 6736 | 83.5 |
October 2011 | Fair | Good | Very Good | Satisfactory | 6736 | 83.5 |
October 2009 | Fair | Good | Very Good | Satisfactory | 6736 | 83.5 |
October 2007 | Fair | Good | Very Good | Satisfactory | 6692 | 83.5 |
October 2005 | Fair | Good | Very Good | Satisfactory | 6692 | 83.5 |
October 2003 | Fair | Good | Very Good | Satisfactory | 4600 | 86.6 |
July 2001 | Fair | Good | Very Good | Satisfactory | 4600 | 86.6 |
July 1999 | Fair | Good | Very Good | Satisfactory | 4600 | 92.0 |
July 1997 | Good | Good | Very Good | Good | 4600 | 84.6 |
October 1995 | Fair | Satisfactory | Very Good | Good | 3000 | 87.1 |
October 1993 | Fair | Satisfactory | Very Good | Good | 3000 | 87.1 |
April 1991 | Good | Very Good | Very Good | Good | 3000 | 87.1 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 320 | 318 | 2 | 0 | 0 |
Steel Protective Coating | sq. ft. | 23,040 | 23,030 | 10 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 1,376 | 1,376 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 1,216 | 1,186 | 20 | 10 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 172 | 143 | 26 | 3 | 0 |
Bearings |
Movable Bearing | each | 10 | 9 | 1 | 0 | 0 |
Fixed Bearing | each | 10 | 10 | 0 | 0 | 0 |
Bridge Rail |