M-28 over E BR TAHQUEMENON RIVER
Map
Coordinates:
+46.34617, -84.9588746°20'46" N, 84°57'32" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | M-28 over E BR TAHQUEMENON RIVER |
Structure number: | 000000000001600 |
Old structure number: | 17117062000B010 (from 1992 edition) |
Location: | 0.5 MI E STRONGS CORNER |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 54.8 ft. [16.7 m] |
Total length: | 54.8 ft. [16.7 m] |
Roadway width between curbs: | 29.9 ft. [9.1 m] |
Deck width edge-to-edge: | 34.8 ft. [10.6 m] |
Owner: | State Highway Agency [01] |
Year built: | 1926 |
Historic significance: | Bridge is on the National Register of Historic Places [1] |
Design load: | M 13.5 / H 15 [2] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: June 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,753 [as of 2007] |
Truck traffic: | 15% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 84.8 |
Recommended work: | Bridge deck replacement with only incidental widening. [37] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2018 | Fair | Satisfactory | Satisfactory | Good | 1753 | 84.8 |
June 2016 | Fair | Satisfactory | Satisfactory | Good | 1753 | 84.8 |
June 2014 | Fair | Satisfactory | Satisfactory | Good | 1753 | 84.8 |
June 2012 | Fair | Satisfactory | Satisfactory | Satisfactory | 1753 | 84.8 |
June 2010 | Fair | Satisfactory | Satisfactory | Good | 1753 | 84.8 |
June 2008 | Fair | Satisfactory | Satisfactory | Good | 1753 | 84.8 |
June 2006 | Fair | Satisfactory | Satisfactory | Good | 2060 | 82.9 |
June 2004 | Fair | Satisfactory | Satisfactory | Good | 2300 | 82.3 |
June 2002 | Fair | Satisfactory | Satisfactory | Good | 2300 | 82.3 |
July 2000 | Fair | Satisfactory | Fair | Good | 2300 | 70.2 |
October 1998 | Fair | Fair | Fair | Good | 2300 | 74.7 |
October 1996 | Poor | Poor | Fair | Good | 2300 | 56.2 |
September 1994 | Poor | Poor | Fair | Good | 1600 | 59.6 |
September 1992 | Fair | Satisfactory | Fair | Good | 1600 | 71.8 |
November 1990 | Fair | Fair | Fair | Good | 1600 | 70.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 495 | 458 | 25 | 12 | 0 |
Steel Protective Coating | sq. ft. | 548 | 398 | 150 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 1,925 | 1,895 | 30 | 0 | 0 |
Wearing Surfaces | sq. ft. | 1,925 | 1,910 | 15 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 1,925 | 1,733 | 192 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 70 | 62 | 8 | 0 | 0 |
Bearings |
Enclosed/Concealed Bearing | each | 18 | 18 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 110 | 0 | 55 | 55 | 0 |