Share:

US-127 over LIME CREEK

Map

Coordinates:
+41.77872, -84.36116
41°46'43" N, 84°21'40" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US-127 over LIME CREEK
Structure number:000000000003272
Old structure number:30130071000B020 (from 1992 edition)
Location:4.8 MI N OHIO STATE LINE
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:24.0 ft. [7.3 m]
Total length:24.0 ft. [7.3 m]
Roadway width between curbs:37.7 ft. [11.5 m]
Deck width edge-to-edge:86.0 ft. [26.2 m]
Owner:State Highway Agency [01]
Year built:1946
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Main span material:Concrete [1]
Main span design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:3,056 [as of 2007]
Truck traffic:17% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:98.3

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
May 2018Fair6 out of 10305698.3
May 2016Fair6 out of 10305698.3
May 2014Fair6 out of 10305698.3
May 2012Fair6 out of 10305698.3
May 2010Fair6 out of 10305698.3
May 2008Fair6 out of 10305698.3
May 2006Fair6 out of 10253798.4
May 2004Fair5 out of 10330087.1
May 2002-N out of 10330098.2
June 2000Fair6 out of 10330098.2
October 1998-N out of 10330098.2
October 1996GoodN out of 10330096.2
November 1994GoodN out of 10290096.3
May 1992GoodN out of 10290096.3
June 1990GoodN out of 10290096.3

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Reinforced Concrete Pile Cap/Footinglinear ft.170164600
Culvert
Reinforced Concrete Culvertlinear ft.85671530