Share:

US-23 NB over CENTER RD

Map

Coordinates:
+42.73712, -83.76381
42°44'14" N, 83°45'50" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US-23 NB over CENTER RD
Structure number:000000000005753
Old structure number:47147014000S071 (from 1992 edition)
Location:3.4 MI S OF GENESEE COL
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:40.4 ft. [12.3 m]
Total length:107.9 ft. [32.9 m]
Roadway width between curbs:42.0 ft. [12.8 m]
Deck width edge-to-edge:47.2 ft. [14.4 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Owner:State Highway Agency [01]
Year built:1961
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Epoxy Overlay [5]

Latest Available Inspection: August 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:25,200 [as of 2016]
Truck traffic:9% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present desirable criteria [8]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:97.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2018FairSatisfactorySatisfactoryGood2520097.0
August 2017FairSatisfactorySatisfactoryGood2520097.0
August 2015FairSatisfactoryFairFair2407986.0
August 2014FairSatisfactoryFairFair2407986.0
May 2013FairSatisfactoryFairFair2407986.0
May 2011FairSatisfactorySatisfactorySatisfactory2407997.0
September 2009FairGoodSatisfactorySatisfactory2407997.0
May 2007FairGoodSatisfactorySatisfactory2606197.0
June 2005FairSatisfactorySatisfactorySatisfactory4100097.0
June 2003FairSatisfactorySatisfactoryGood4100097.0
June 2001FairSatisfactorySatisfactoryGood4100097.0
August 1999FairSatisfactorySatisfactoryGood4100097.0
September 1997PoorFairFairPoor4100069.0
October 1995PoorFairFairPoor3300069.0
November 1993FairGoodSatisfactoryExcellent1400097.0
March 1991FairSatisfactorySatisfactorySatisfactory1400097.0
May 1989FairFairSatisfactoryFair1400085.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.864860400
Deck
Reinforced Concrete Decksq. ft.5,0944,93882740
Wearing Surfacessq. ft.4,7524,752000
Substructure
Reinforced Concrete Columneach87100
Reinforced Concrete Abutmentlinear ft.1211021810
Reinforced Concrete Pier Caplinear ft.8986300
Joints
Strip Seal Jointlinear ft.8608600
Pourable Jointlinear ft.84740100
Bearings
Elastomeric Bearingeach3203200
Fixed Bearingeach1601420
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.21648541140