GLENBROOK ROAD over PORTAGE RIVER
Map
Coordinates:
+42.42482, -84.0037442°25'29" N, 84°00'13" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | GLENBROOK ROAD over PORTAGE RIVER |
Structure number: | 000000000005833 |
Old structure number: | 47200037000B010 (from 1992 edition) |
Location: | SEC 31-32 PUTNAM TWP |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 9.8 ft. [3.0 m] |
Total length: | 24.0 ft. [7.3 m] |
Roadway width between curbs: | 34.8 ft. [10.6 m] |
Deck width edge-to-edge: | 35.1 ft. [10.7 m] |
Skew angle: | 45° |
Owner: | County Highway Agency [02] |
Year built: | 1960 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 2 |
Main spans material: | Steel [3] |
Main spans design: | Culvert [19] |
Deck type: | Not applicable [N] |
Latest Available Inspection: October 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 640 [as of 2014] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Culvert condition: | Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5] |
Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
Sufficiency rating: | 85.6 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
October 2018 | Fair | 5 out of 10 | 640 | 85.6 |
October 2016 | Fair | 5 out of 10 | 640 | 85.6 |
October 2014 | Fair | 5 out of 10 | 640 | 85.6 |
October 2012 | Fair | 5 out of 10 | 580 | 85.7 |
October 2010 | Fair | 5 out of 10 | 730 | 61.8 |
October 2008 | Fair | 5 out of 10 | 730 | 61.8 |
August 2006 | Good | 7 out of 10 | 858 | 71.8 |
August 2004 | Good | 7 out of 10 | 858 | 71.8 |
July 2002 | - | N out of 10 | 858 | 71.8 |
March 2000 | Good | 7 out of 10 | 939 | 71.7 |
September 1997 | Good | 7 out of 10 | 939 | 71.7 |
September 1995 | Good | 7 out of 10 | 210 | 87.8 |
October 1993 | Good | 7 out of 10 | 210 | 87.8 |
June 1991 | Good | 7 out of 10 | 210 | 87.8 |