I-75 & RAMPS C&D over M-8 DAVISON & SERVIC RDS
Map
Coordinates:
+42.40864, -83.0790842°24'31" N, 83°04'45" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I-75 & RAMPS C&D over M-8 DAVISON & SERVIC RDS |
Structure number: | 000000000011867 |
Old structure number: | 82182252000S310 (from 1992 edition) |
Location: | IN DETROIT |
Purpose: | Carries highway overpass over highway |
Route classification: | Principal Arterial - Interstate (Urban) [11] |
Length of largest span: | 64.0 ft. [19.5 m] |
Total length: | 260.8 ft. [79.5 m] |
Roadway width between curbs: | 209.7 ft. [63.9 m] |
Deck width edge-to-edge: | 212.9 ft. [64.9 m] |
Vertical clearance above deck: | 14.8 ft. [4.5 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Skew angle: | 15° |
Owner: | State Highway Agency [01] |
Year built: | 1969 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 4 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: April 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, would be posted or closed except for temporary shoring [D] |
Average daily traffic: | 159,874 [as of 2007] |
Truck traffic: | 8% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Underclearances appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 28.0 |
Recommended work: | Bridge deck replacement with only incidental widening. [37] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2018 | Fair | Fair | Good | Satisfactory | 159874 | 28.0 |
May 2016 | Fair | Fair | Good | Satisfactory | 159874 | 28.0 |
May 2014 | Fair | Fair | Good | Fair | 159874 | 76.0 |
May 2012 | Fair | Fair | Good | Fair | 159874 | 76.0 |
May 2010 | Fair | Satisfactory | Good | Good | 159874 | 88.0 |
July 2009 | Fair | Satisfactory | Good | Good | 159874 | 88.0 |
July 2007 | Fair | Satisfactory | Good | Good | 160728 | 88.0 |
July 2005 | Fair | Satisfactory | Good | Good | 118200 | 88.0 |
July 2003 | Fair | Fair | Satisfactory | Fair | 118200 | 76.0 |
June 2001 | Fair | Fair | Satisfactory | Fair | 118200 | 76.0 |
July 2000 | Poor | Fair | Satisfactory | Serious | 118200 | 49.0 |
September 1998 | Poor | Fair | Satisfactory | Serious | 118200 | 49.0 |
August 1997 | Poor | Fair | Satisfactory | Poor | 118200 | 66.0 |
October 1996 | Poor | Good | Good | Poor | 118200 | 67.0 |
October 1994 | Fair | Satisfactory | Very Good | Fair | 118200 | 83.0 |
August 1992 | Fair | Good | Very Good | Fair | 118200 | 83.0 |
July 1990 | Fair | Satisfactory | Very Good | Fair | 118200 | 83.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 7,306 | 7,266 | 40 | 0 | 0 |
Steel Protective Coating | sq. ft. | 65,754 | 65,654 | 100 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 55,539 | 54,989 | 500 | 50 | 0 |
Substructure |
Reinforced Concrete Column | each | 35 | 35 | 0 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 3,629 | 3,629 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 404 | 373 | 31 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 1,600 | 1,568 | 32 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 610 | 600 | 8 | 2 | 0 |
Concrete Protective Coating | sq. ft. | 11,600 | 11,484 | 116 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 212 | 210 | 2 | 0 | 0 |
Pourable Joint | linear ft. | 1,260 | 840 | 0 | 420 | 0 |
Bearings |
Movable Bearing | each | 106 | 100 | 6 | 0 | 0 |
Fixed Bearing | each | 54 | 50 | 4 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 1,427 | 350 | 1,072 | 5 | 0 |
Concrete Protective Coating | sq. ft. | 3,400 | 3,230 | 170 | 0 | 0 |