Share:

CSAH 66(BROADWAY) over NE SIBLEY ST

Map

Coordinates:
+44.99879, -93.27257
44°59'56" N, 93°16'21" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CSAH 66(BROADWAY) over NE SIBLEY ST
Structure number:27660
Location:0.2 MI W OF JCT CSAH 23
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:80.4 ft. [24.5 m]
Total length:86.0 ft. [26.2 m]
Roadway width between curbs:52.2 ft. [15.9 m]
Deck width edge-to-edge:70.2 ft. [21.4 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:31°
Owner:County Highway Agency [02]
Year built:1986
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: June 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:19,900 [as of 2005]
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:79.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2017GoodGoodGoodGood1990079.5
June 2015GoodGoodGoodGood1990079.5
June 2013GoodGoodGoodGood1990079.5
June 2011GoodGoodGoodGood1990079.5
June 2009GoodGoodGoodGood1990079.5
November 2007GoodGoodGoodGood1990079.5
October 2005GoodGoodGoodGood2260079.0
October 2003GoodGoodVery GoodGood2130079.3
October 2001GoodGoodVery GoodGood1770079.9
October 1999GoodGoodVery GoodGood1820078.8
October 1997GoodGoodVery GoodGood1820077.8
October 1996GoodGoodVery GoodGood1850077.7
November 1994GoodGoodVery GoodGood1850077.5
August 1994GoodGoodVery GoodGood1850077.5
October 1993GoodGoodVery GoodGood1850077.5
October 1992GoodGoodVery GoodGood1860077.5
August 1992GoodGoodVery GoodGood1830077.6

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.7387174170
Steel Protective Coatingsq. ft.10,6206,9223,5988020
Deck
Reinforced Concrete Decksq. ft.6,0536,0361610
Wearing Surfacessq. ft.4,4784,4393900
Substructure
Reinforced Concrete Abutmentlinear ft.1921434810
Joints
Strip Seal Jointlinear ft.1570147100
Bearings
Elastomeric Bearingeach1310300
Fixed Bearingeach55000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.274267700
Steel Protective Coatingsq. ft.5480053810
Reinforced Concrete Bridge Raillinear ft.2742502220