Share:

Linden Ave over I 394

Map

Coordinates:
+44.97592, -93.28178
44°58'33" N, 93°16'54" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:Linden Ave over I 394
Structure number:27701
Location:0.3 MI NE OF JCT TH 94
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:104.3 ft. [31.8 m]
Total length:183.4 ft. [55.9 m]
Roadway width between curbs:41.3 ft. [12.6 m]
Deck width edge-to-edge:52.2 ft. [15.9 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Skew angle:45°
Owner:State Highway Agency [01]
Year built:1985
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:3,000 [as of 2005]
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:86.9

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017FairFairSatisfactorySatisfactory300086.9
June 2015FairSatisfactorySatisfactoryGood300086.9
June 2013FairSatisfactorySatisfactoryGood300086.9
June 2011FairSatisfactorySatisfactoryGood300086.9
October 2009FairSatisfactorySatisfactoryGood300086.9
November 2007FairSatisfactorySatisfactoryGood300086.9
July 2006FairSatisfactorySatisfactoryGood300086.9
December 2004FairSatisfactorySatisfactoryGood320086.9
October 2002FairSatisfactorySatisfactoryGood730080.1
October 2001FairSatisfactorySatisfactoryGood730080.1
November 2000FairGoodSatisfactoryGood730080.1
June 1999FairGoodSatisfactoryGood730080.1
June 1998FairGoodSatisfactoryGood730080.1
June 1996GoodGoodGoodGood100089.4
August 1995GoodGoodGoodGood100093.9
August 1994GoodGoodGoodGood100093.9
November 1993GoodGoodGoodGood100093.9
January 1993GoodGoodGoodGood100093.9
November 1991FairGoodVery GoodSatisfactory100093.9

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,09808582400
Steel Protective Coatingsq. ft.16,430013,9651,643822
Deck
Reinforced Concrete Decksq. ft.9,5878,911696070
Wearing Surfacessq. ft.7,5897,47396200
Substructure
Reinforced Concrete Columneach33000
Reinforced Concrete Abutmentlinear ft.20410176270
Reinforced Concrete Pier Caplinear ft.6458330
Joints
Strip Seal Jointlinear ft.132130101
Bearings
Elastomeric Bearingeach146710
Fixed Bearingeach40400
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.1701452320
Steel Protective Coatingsq. ft.1,02038751010023
Reinforced Concrete Bridge Raillinear ft.360239103180