Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I 94 over GLENWOOD AVE; RRS
Structure number:27727
Location:0.3 MI N OF JCT TH 394
Purpose:Carries highway over highway and railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:137.1 ft. [41.8 m]
Total length:1511.2 ft. [460.6 m]
Roadway width between curbs:101.1 ft. [30.8 m]
Deck width edge-to-edge:109.9 ft. [33.5 m]
Vertical clearance below bridge:23.0 ft. [7.0 m]
Owner:State Highway Agency [01]
Year built:1978
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:6
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:117,000 [as of 2004]
Truck traffic:4% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:69.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017FairSatisfactorySatisfactoryFair11700069.0
June 2015FairSatisfactorySatisfactoryFair11700069.0
May 2013FairSatisfactorySatisfactorySatisfactory11700081.3
May 2011FairSatisfactorySatisfactorySatisfactory11700081.3
September 2009FairSatisfactorySatisfactorySatisfactory11700081.4
July 2008FairSatisfactorySatisfactorySatisfactory11700080.4
June 2007FairSatisfactorySatisfactorySatisfactory11700080.4
May 2006FairSatisfactorySatisfactorySatisfactory11700080.4
August 2005FairSatisfactorySatisfactorySatisfactory11700080.4
July 2004FairSatisfactorySatisfactorySatisfactory11800080.3
July 2003FairSatisfactorySatisfactorySatisfactory11800080.3
June 2002FairSatisfactorySatisfactorySatisfactory12800079.3
October 2001FairSatisfactorySatisfactorySatisfactory12800079.3
March 2001FairGoodGoodSatisfactory12800078.1
October 1999FairGoodGoodSatisfactory12800078.1
August 1998FairGoodGoodSatisfactory12800078.1
August 1997GoodGoodGoodGood12800083.5
October 1996GoodGoodGoodGood12800083.5
September 1995GoodGoodVery GoodGood10000081.9
September 1994GoodGoodVery GoodGood9800087.6
October 1993GoodGoodVery GoodGood9800087.6
October 1992GoodGoodVery GoodGood8200088.8
June 1991FairSatisfactoryVery GoodGood8200088.8

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.8,65707,7918660
Steel Protective Coatingsq. ft.151,7660136,58412,2722,910
Prestressed Concrete Girder/Beamlinear ft.11,91811,622248480
Deck
Reinforced Concrete Decksq. ft.181,722177,4853,1431,06331
Wearing Surfacessq. ft.170,575170,575000
Substructure
Reinforced Concrete Columneach89741500
Reinforced Concrete Pier Walllinear ft.190190000
Reinforced Concrete Abutmentlinear ft.29324120320
Reinforced Concrete Pier Caplinear ft.1,5531,078434410
Joints
Strip Seal Jointlinear ft.1,07001,07000
Pourable Jointlinear ft.1,1181,118000
Bearings
Elastomeric Bearingeach142014200
Movable Bearingeach6936600
Fixed Bearingeach129289560
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.5,772964,8718050