Share:

I 94 WB ON RAMP over I 35W; SB ON RAMP

Map

Coordinates:
+44.96642, -93.25484
44°57'59" N, 93°15'17" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I 94 WB ON RAMP over I 35W; SB ON RAMP
Structure number:27850
Location:AT THE EAST JCT TH 94
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:88.9 ft. [27.1 m]
Total length:361.9 ft. [110.3 m]
Roadway width between curbs:36.7 ft. [11.2 m]
Deck width edge-to-edge:40.0 ft. [12.2 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Skew angle:39°
Owner:State Highway Agency [01]
Year built:1967
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:5
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: May 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:7,300 [as of 1994]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:86.2

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2018FairSatisfactorySatisfactoryFair730086.2
September 2016GoodGoodGoodGood730097.3
September 2014GoodGoodGoodGood730097.3
September 2012GoodGoodGoodGood730097.3
July 2010GoodGoodGoodGood730097.3
October 2008GoodGoodGoodGood730097.3
November 2007GoodGoodGoodGood730097.3
October 2006GoodGoodGoodGood730097.3
December 2005GoodGoodGoodGood730097.3
September 2004GoodGoodGoodGood730097.3
September 2003GoodGoodGoodGood730097.3
July 2002GoodGoodGoodGood730097.3
June 2001GoodGoodGoodGood730097.3
January 2001GoodGoodGoodGood730097.3
November 1999GoodGoodGoodGood1180000.0
August 1998FairGoodFairGood730086.2
November 1997FairExcellentSatisfactoryGood730097.7
August 1996FairVery GoodSatisfactoryGood730097.7
May 1995FairFairGoodGood730096.4
October 1993FairFairGoodGood730096.4
October 1992FairFairGoodGood730096.4
December 1991PoorSatisfactoryPoorGood730070.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,7821,1824501500
Steel Protective Coatingsq. ft.20,965012,7157,500750
Deck
Reinforced Concrete Decksq. ft.14,48014,22625400
Wearing Surfacessq. ft.13,28312,84344000
Substructure
Reinforced Concrete Columneach129300
Reinforced Concrete Abutmentlinear ft.109436060
Reinforced Concrete Pier Caplinear ft.1921756110
Joints
Strip Seal Jointlinear ft.102102000
Pourable Jointlinear ft.101881300
Bearings
Movable Bearingeach27121050
Fixed Bearingeach33000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.72862510300