Share:

CEDAR (10TH) over MISS R; BNSF STS

Map

Coordinates:
+44.97871, -93.24371
44°58'43" N, 93°14'37" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CEDAR (10TH) over MISS R; BNSF STS
Structure number:2796
Location:0.3 MI N OF WASH AVE
Purpose:Carries highway and pedestrian walkway over highway, waterway, and railroad
Route classification:Minor Arterial (Urban) [16]
Length of largest span:290.4 ft. [88.5 m]
Total length:2153.0 ft. [656.2 m]
Roadway width between curbs:55.4 ft. [16.9 m]
Deck width edge-to-edge:68.2 ft. [20.8 m]
Vertical clearance below bridge:88.6 ft. [27.0 m]
Owner:City or Municipal Highway Agency [04]
Year built:1929
Historic significance:Bridge is on the National Register of Historic Places [1]
Design load:MS 18 / HS 20 [5]
Number of main spans:7
Main spans material:Concrete [1]
Main spans design:Arch - Deck [11]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: September 2018

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:8,600 [as of 2017]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Countermeasures have been installed to mitigate an existing problem with scour. [7]
Sufficiency rating:38.1

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2018PoorSatisfactoryPoorFair860038.1
September 2017PoorSatisfactoryPoorFair860038.1
September 2016PoorSatisfactoryPoorFair997537.7
September 2015PoorSatisfactoryPoorFair997537.7
September 2014FairSatisfactoryFairFair997554.9
September 2013FairSatisfactoryFairFair2445252.1
September 2012FairSatisfactoryFairFair2445252.1
September 2011FairSatisfactoryFairFair2445252.1
August 2010FairSatisfactorySatisfactorySatisfactory2445262.9
September 2009FairSatisfactorySatisfactorySatisfactory2445259.9
October 2008FairSatisfactorySatisfactorySatisfactory2445272.3
July 2007GoodGoodGoodGood1010077.1
September 2006GoodGoodGoodGood1010077.1
May 2005GoodGoodGoodGood1160076.9
June 2004GoodGoodGoodGood1160076.9
August 2003GoodGoodGoodGood1030077.1
August 2002GoodGoodGoodGood1430076.6
September 2001GoodGoodGoodGood1430076.6
September 2000GoodGoodGoodGood1200077.7
July 1999GoodGoodGoodGood25000.0
May 1998GoodGoodGoodGood1200077.7
May 1997GoodGoodGoodGood1430074.8
July 1996GoodGoodGoodGood1430074.8
July 1995GoodGoodGoodGood1230074.5
June 1994GoodGoodGoodGood1250074.4
June 1993GoodGoodGoodGood1100074.6
June 1992GoodGoodGoodGood936074.8

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2,5791,3791,20000
Steel Protective Coatingsq. ft.21,715021,2504650
Prestressed Concrete Girder/Beamlinear ft.5,98705,900870
Deck
Reinforced Concrete Decksq. ft.69,700062,3707,3300
Wearing Surfacessq. ft.56,888055,6881,2000
Superstructure
Reinforced Concrete Archlinear ft.2,28701,1731,1140
Substructure
Reinforced Concrete Columneach4104100
Reinforced Concrete Pier Walllinear ft.2990269300
Reinforced Concrete Abutmentlinear ft.175017500
Reinforced Concrete Pier Caplinear ft.1,29301,1831100
Joints
Strip Seal Jointlinear ft.333033300
Pourable Jointlinear ft.2,62802,62602
Compression Jointlinear ft.63032031
Bearings
Movable Bearingeach9309300
Fixed Bearingeach105545100
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.4,5201,1303,39000
Steel Protective Coatingsq. ft.19,377019,37700
Reinforced Concrete Bridge Raillinear ft.2,26002,26000
Deck
Reinforced Concrete Slabsq. ft.77,384070,0547,3300
Wearing Surfacessq. ft.63,159061,9591,2000