Share:

CSAH 122(WASH. AV) over MISS. RIVER; STREETS

Map

Coordinates:
+44.97353, -93.23797
44°58'25" N, 93°14'17" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CSAH 122(WASH. AV) over MISS. RIVER; STREETS
Structure number:9360
Location:0.6 MI E OF JCT TH 35W
Purpose:Carries highway over highway and waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:315.3 ft. [96.1 m]
Total length:1131.0 ft. [344.7 m]
Roadway width between curbs:58.1 ft. [17.7 m]
Deck width edge-to-edge:71.9 ft. [21.9 m]
Vertical clearance above deck:17.4 ft. [5.3 m]
Vertical clearance below bridge:52.5 ft. [16.0 m]
Owner:County Highway Agency [02]
Year built:1965
Year reconstructed:2000
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Number of main spans:5
Main spans material:Steel continuous [4]
Main spans design:Girder and floorbeam system [03]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: August 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:18,800 [as of 2005]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Countermeasures have been installed to mitigate an existing problem with scour. [7]
Sufficiency rating:90.3

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2017FairGoodSatisfactorySatisfactory1880090.3
August 2015FairGoodSatisfactorySatisfactory1880094.5
August 2013FairGoodSatisfactorySatisfactory1880094.5
April 2010FairFairSatisfactorySatisfactory1880091.5
July 2009FairFairSatisfactorySatisfactory1880091.5
April 2008FairFairSatisfactorySatisfactory1880091.5
October 2007GoodGoodGoodGood1880092.5
October 2006GoodGoodGoodGood1880094.5
November 2005GoodGoodGoodGood2150093.9
November 2004GoodGoodGoodGood2150095.0
October 2003GoodGoodGoodGood1870095.6
September 2002GoodGoodGoodGood1870095.6
October 2001GoodGoodGoodGood1880095.6
November 2000FairGoodGoodSatisfactory1880093.5
October 1999FairSatisfactorySatisfactoryFair43000.0
December 1998FairSatisfactoryGoodFair2400079.3
November 1997FairSatisfactoryGoodFair2400080.6
June 1995FairSatisfactoryGoodSatisfactory2400089.4
June 1993FairSatisfactoryGoodSatisfactory2400089.4
August 1992FairSatisfactoryGoodSatisfactory2500089.2
September 1991FairSatisfactoryGoodSatisfactory2500089.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.4,8403,2621,508700
Steel Protective Coatingsq. ft.149,000121,91218,0009,00088
Steel Stringerlinear ft.17,39014,8172,520530
Steel Protective Coatingsq. ft.88,07481,2323,4121,7061,724
Deck
Reinforced Concrete Decksq. ft.182,848180,6652,18120
Wearing Surfacessq. ft.164,873162,9481,91780
Superstructure
Steel Trusslinear ft.4,2604,260000
Steel Protective Coatingsq. ft.25,90025,00090000
Steel Floor Beamlinear ft.10,1979,2096083800
Steel Protective Coatingsq. ft.108,50999,4314,3883,6041,086
Steel Pin or Pin & Hangar Assemblyeach188969200
Steel Protective Coatingsq. ft.1881620206
Steel Gusset Plateeach722722000
Substructure
Steel Columneach1745790270
Steel Protective Coatingsq. ft.28,75627,4341,044164114
Reinforced Concrete Columneach2015500
Reinforced Concrete Pier Walllinear ft.26754881250
Reinforced Concrete Abutmentlinear ft.31226728170
Reinforced Concrete Pile Cap/Footinglinear ft.1826911300
Reinforced Concrete Pier Caplinear ft.2892374660
Joints
Strip Seal Jointlinear ft.218218000
Pourable Jointlinear ft.682434100
Assembly with Sealeach144144000
Assembly without Seal Jointlinear ft.1,39801,39800
Bearings
Movable Bearingeach501029110
Fixed Bearingeach34231100
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.2,810802,73000
Steel Protective Coatingsq. ft.9,83535009,40580
Reinforced Concrete Bridge Raillinear ft.4,6844,6305220