Share:

E 2ND ST over STINSON CR

This bridge is no longer in the current National Bridge Inventory database, and has likely been demolished or abandoned.

Map

Coordinates:
+38.82728, -91.94754
38°49'38" N, 91°56'51" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:E 2ND ST over STINSON CR
Structure number:17547
Old structure number:U1555003 014 (from 1992 edition)
Location:S 17 T 47 N R 9 W
Purpose:Carries highway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:60.0 ft. [18.3 m]
Total length:71.9 ft. [21.9 m]
Roadway width between curbs:24.9 ft. [7.6 m]
Deck width edge-to-edge:26.9 ft. [8.2 m]
Owner:City or Municipal Highway Agency [04]
Year built:1920
Year reconstructed:1979
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Concrete [1]
Main span design:Arch - Deck [11]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: March 2009

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:5,790 [as of 2009]
Truck traffic:15% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:47.1
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$617,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2009FairSatisfactorySatisfactoryFair579047.1
April 1999FairSatisfactorySatisfactoryFair579046.4
January 1991GoodGoodGoodVery Good579051.8