Share:

OLD RTE 60 over CREEK

Map

Coordinates:
+36.99848, -91.35852
36°59'55" N, 91°21'31" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:OLD RTE 60 over CREEK
Structure number:21415
Old structure number:3050012 101 (from 1992 edition)
Location:S 23 T 27 N R 4 W
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:14.1 ft. [4.3 m]
Total length:28.9 ft. [8.8 m]
Roadway width between curbs:51.8 ft. [15.8 m]
Deck width edge-to-edge:54.1 ft. [16.5 m]
Owner:County Highway Agency [02]
Year built:1929
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: January 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:75 [as of 2015]
Truck traffic:10% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:77.8

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
January 2017Good7 out of 107577.8
January 2015Good7 out of 107577.8
January 2013Good7 out of 107577.8
May 2010Good7 out of 107577.8
January 2008Good7 out of 107577.8
January 2006Good7 out of 107577.8
February 2004Good7 out of 107577.8
December 2002Good7 out of 107577.8
July 2000Good7 out of 107577.8
January 1998Good7 out of 107577.8
December 1990Good7 out of 107574.8