Share:

RT F E over BR OF PATTERSON CR

Map

Coordinates:
+36.65385, -94.45219
36°39'14" N, 94°27'08" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RT F E over BR OF PATTERSON CR
Structure number:8123
Old structure number:R 117 1 (from 1992 edition)
Location:S 12 T 22 N R 33 W
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:8.9 ft. [2.7 m]
Total length:28.9 ft. [8.8 m]
Roadway width between curbs:26.6 ft. [8.1 m]
Deck width edge-to-edge:28.5 ft. [8.7 m]
Skew angle:50°
Owner:State Highway Agency [01]
Year built:1961
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: October 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:1,202 [as of 2017]
Truck traffic:15% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:65.9

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
October 2018Good7 out of 10120265.9
October 2016Good7 out of 10119266.0
October 2014Good7 out of 10145849.5
December 2012Good7 out of 10107449.5
October 2010Good7 out of 10113049.5
January 2009Good7 out of 10116649.5
January 2007Good7 out of 10124649.5
November 2004Good7 out of 10119249.5
December 2002Good7 out of 10120049.5
October 2000Good7 out of 10122349.5
September 1998Good7 out of 10118749.5
November 1996Good7 out of 10118749.5
January 1995Good8 out of 10120149.2
October 1992Good8 out of 10118158.2
February 1991Good8 out of 10111347.7