I 15 over DRY FORK MARIAS RIVER
Map
Coordinates:
+48.21717, -111.9334648°13'02" N, 111°56'00" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I 15 over DRY FORK MARIAS RIVER |
Structure number: | I00015342+00252 |
Location: | 2M N CONRAD |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Length of largest span: | 71.5 ft. [21.8 m] |
Total length: | 247.1 ft. [75.3 m] |
Roadway width between curbs: | 41.3 ft. [12.6 m] |
Deck width edge-to-edge: | 44.3 ft. [13.5 m] |
Owner: | State Highway Agency [01] |
Year built: | 1972 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 4 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: September 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,799 [as of 2016] |
Truck traffic: | 22% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 97.9 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
September 2017 | Fair | Satisfactory | Good | Good | 1799 | 97.9 |
September 2013 | Fair | Satisfactory | Good | Good | 3430 | 97.8 |
September 2009 | Fair | Satisfactory | Good | Good | 3810 | 97.8 |
September 2005 | Good | Good | Very Good | Good | 3950 | 97.8 |
September 2001 | Good | Good | Very Good | Good | 3690 | 96.8 |
April 1999 | Good | Very Good | Very Good | Very Good | 3380 | 97.8 |
December 1996 | Good | Very Good | Very Good | Very Good | 3050 | 97.9 |
October 1992 | Good | Very Good | Very Good | Very Good | 2840 | 97.8 |
January 1991 | Good | Very Good | Very Good | Very Good | 2920 | 97.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 1,519 | 1,517 | 2 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 10,904 | 10,904 | 0 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 10,904 | 10,904 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 9 | 9 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 105 | 87 | 18 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 131 | 131 | 0 | 0 | 0 |
Bearings |
Fixed Bearing | each | 38 | 26 | 12 | 0 | 0 |
Steel Protective Coating | sq. ft. | 38 | 29 | 3 | 3 | 3 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 495 | 371 | 124 | 0 | 0 |
Steel Protective Coating | sq. ft. | 825 | 497 | 164 | 82 | 82 |