Share:

PREPUTIN RD over PONDERA COULEE 011

Map

Coordinates:
+48.12393, -111.53687
48°07'26" N, 111°32'13" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PREPUTIN RD over PONDERA COULEE 011
Structure number:L37201003+06001
Location:16M NE BRADY
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:79.1 ft. [24.1 m]
Total length:79.1 ft. [24.1 m]
Roadway width between curbs:25.6 ft. [7.8 m]
Deck width edge-to-edge:26.2 ft. [8.0 m]
Owner:County Highway Agency [02]
Year built:1960
Year reconstructed:1992
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Corrugated Steel [6]
Wearing surface:Bituminous [6]

Latest Available Inspection: December 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:100 [as of 2002]
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:90.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2017GoodGoodGoodGood10090.7
November 2016GoodGoodGoodGood10090.7
November 2014GoodGoodGoodGood10092.7
November 2012GoodGoodGoodGood10092.7
December 2010GoodGoodGoodGood10092.7
November 2008GoodGoodGoodGood10091.7
November 2006GoodGoodGoodGood10091.7
November 2004GoodVery GoodGoodGood10091.7
October 2002GoodVery GoodGoodGood10091.7
June 2001GoodVery GoodGoodGood10091.7
May 1999GoodVery GoodVery GoodVery Good10064.2
April 1997GoodVery GoodVery GoodVery Good10064.2
December 1994GoodVery GoodVery GoodVery Good9664.2
February 1993GoodVery GoodVery GoodVery Good9666.4
February 1991GoodGoodVery GoodGood9666.4

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.47633713900
Steel Protective Coatingsq. ft.4,3602,180872436872
Substructure
Steel Columneach1201200
Steel Protective Coatingsq. ft.320160643264
Steel Abutmentlinear ft.1251141100
Steel Protective Coatingsq. ft.751600753838
Steel Pier Caplinear ft.5205200
Steel Protective Coatingsq. ft.17386351735
Deck
Corrugated or Orthotropic Decksq. ft.2,0882,088000
Wearing Surfacessq. ft.2,0882,088000
Steel Protective Coatingsq. ft.2,0882,088000
Bearings
Fixed Bearingeach1201200
Steel Protective Coatingsq. ft.128112
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.1571233400
Steel Protective Coatingsq. ft.4053640041