Share:

S 7 over FLASTED DRAW

Map

Coordinates:
+45.96009, -104.50658
45°57'36" N, 104°30'24" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:S 7 over FLASTED DRAW
Structure number:P00027005+06231
Location:5M NE EKALAKA
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:19.0 ft. [5.8 m]
Total length:58.4 ft. [17.8 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:25.9 ft. [7.9 m]
Owner:State Highway Agency [01]
Year built:1940
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Wood or timber [7]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Wood or Timber [8]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:417 [as of 2017]
Truck traffic:8% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:86.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2018FairGoodSatisfactorySatisfactory41786.0
October 2016FairGoodSatisfactorySatisfactory40087.1
October 2014FairGoodSatisfactorySatisfactory44085.9
October 2012FairGoodSatisfactoryGood44085.9
October 2010FairGoodSatisfactoryGood44085.9
September 2008FairGoodSatisfactoryGood40088.0
January 2007FairGoodSatisfactoryFair32077.1
February 2005FairGoodSatisfactoryFair32069.8
February 2003FairGoodSatisfactoryFair31069.8
January 2001FairGoodSatisfactoryGood31080.9
January 1999FairGoodSatisfactoryFair30069.8
December 1996FairGoodSatisfactoryGood27279.0
January 1995GoodVery GoodGoodVery Good23481.0
November 1992GoodVery GoodVery GoodVery Good23975.0
February 1991GoodVery GoodVery GoodVery Good25969.9

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Timber Girder/Beamlinear ft.74163710400
Substructure
Timber Abutmentlinear ft.85424300
Timber Pileeach2021530
Timber Pier Caplinear ft.121113800
Deck
Timber Decksq. ft.1,5181,4427600
Wearing Surfacessq. ft.1,5181,275213300
Bridge Rail