US74 EBL over GOULDS FORK CREEK
Map
Coordinates:
+34.97987, -80.1239634°58'48" N, 80°07'26" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US74 EBL over GOULDS FORK CREEK |
Structure number: | 000000000070049 |
Old structure number: | 000000000007049 (from 1992 edition) |
Location: | 0.4 MI. E. JCT. SR1207 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 39.0 ft. [11.9 m] |
Total length: | 120.1 ft. [36.6 m] |
Roadway width between curbs: | 39.7 ft. [12.1 m] |
Deck width edge-to-edge: | 42.7 ft. [13.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1970 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 3 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 9,000 [as of 2015] |
Truck traffic: | 14% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 96.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2017 | Good | Good | Good | Good | 9000 | 96.2 |
April 2015 | Good | Good | Good | Good | 17000 | 95.4 |
April 2013 | Good | Good | Good | Good | 9000 | 96.2 |
April 2011 | Fair | Satisfactory | Good | Very Good | 8000 | 95.3 |
April 2009 | Fair | Satisfactory | Good | Very Good | 8000 | 95.3 |
April 2007 | Fair | Satisfactory | Good | Very Good | 8500 | 90.2 |
April 2005 | Fair | Satisfactory | Good | Very Good | 8500 | 90.2 |
March 2003 | Fair | Satisfactory | Good | Very Good | 8500 | 95.2 |
May 2001 | Fair | Satisfactory | Good | Very Good | 7500 | 95.3 |
March 1999 | Fair | Satisfactory | Good | Very Good | 7750 | 95.3 |
February 1997 | Good | Good | Very Good | Very Good | 6200 | 95.4 |
March 1995 | Good | Good | Very Good | Very Good | 6200 | 95.5 |
March 1993 | Good | Good | Very Good | Very Good | 5750 | 95.6 |
March 1991 | Good | Good | Very Good | Very Good | 5750 | 95.6 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 702 | 701 | 1 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 5,098 | 0 | 0 | 5,098 | 0 |
Substructure |
Prestressed Concrete Column | each | 10 | 10 | 0 | 0 | 0 |
Other Material Abutment | linear ft. | 86 | 85 | 1 | 0 | 0 |
Prestressed Concrete Pile | each | 30 | 30 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 176 | 172 | 4 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 86 | 86 | 0 | 0 | 0 |
Bearings |
Other Bearing | each | 36 | 35 | 1 | 0 | 0 |
Steel Protective Coating | sq. ft. | 108 | 108 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 242 | 242 | 0 | 0 | 0 |