Share:

US13S US17S over ROANOKE RIVER OVER

Map

Coordinates:
+35.87568, -77.03021
35°52'32" N, 77°01'49" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US13S US17S over ROANOKE RIVER OVER
Structure number:000000000150013
Location:2.1 MI.S. OF JCT.SR1521
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:34.1 ft. [10.4 m]
Total length:420.0 ft. [128.0 m]
Roadway width between curbs:24.9 ft. [7.6 m]
Deck width edge-to-edge:30.2 ft. [9.2 m]
Owner:State Highway Agency [01]
Year built:1940
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 9 / H 10 [1]
Number of main spans:12
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: September 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:7,000 [as of 2015]
Truck traffic:14% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:61.0
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2018FairFairFairFair700061.0
September 2016FairFairSatisfactoryFair480060.4
September 2014FairFairSatisfactoryFair480012.6
September 2012FairFairFairFair495012.4
September 2010PoorPoorFairFair550058.0
September 2008PoorPoorFairFair500057.0
December 2006FairFairFairFair495062.0
January 2004FairFairFairFair495062.0
September 2002FairFairFairFair500056.6
September 2000FairFairFairFair475056.7
September 1998FairFairFairFair445058.0
August 1990FairFairFairFair375057.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2,9262,62629190
Steel Protective Coatingsq. ft.16,89816,19440727918
Deck
Reinforced Concrete Decksq. ft.11,8108,3733,3301070
Wearing Surfacessq. ft.10,5149,2721,0541880
Substructure
Reinforced Concrete Abutmentlinear ft.149697370
Prestressed Concrete Pileeach4404040
Reinforced Concrete Pier Caplinear ft.3082871740
Joints
Compression Jointlinear ft.125125000
Bearings
Movable Bearingeach4270350
Steel Protective Coatingsq. ft.7477060
Fixed Bearingeach84560280
Steel Protective Coatingsq. ft.152937052
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.86245801160