SR1503 over CYPRESS CREEK
Map
Coordinates:
+34.78759, -78.5086134°47'15" N, 78°30'31" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR1503 over CYPRESS CREEK |
Structure number: | 000000000170215 |
Location: | 0.6MI.S.JCT.SR1504 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 9.8 ft. [3.0 m] |
Total length: | 23.0 ft. [7.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1970 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 2 |
Main spans material: | Steel [3] |
Main spans design: | Culvert [19] |
Deck type: | Not applicable [N] |
Latest Available Inspection: March 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 210 [as of 2000] |
Truck traffic: | 6% of total traffic |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Culvert condition: | Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 88.9 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
March 2018 | Fair | 5 out of 10 | 210 | 88.9 |
March 2016 | Fair | 5 out of 10 | 210 | 88.9 |
March 2014 | Fair | 5 out of 10 | 210 | 88.8 |
July 2012 | Fair | 5 out of 10 | 210 | 88.8 |
July 2010 | Fair | 6 out of 10 | 210 | 99.9 |
July 2008 | Fair | 6 out of 10 | 210 | 99.9 |
June 2006 | Good | 8 out of 10 | 210 | 99.9 |
January 2004 | Good | 8 out of 10 | 210 | 99.9 |
March 2002 | Good | 8 out of 10 | 210 | 99.9 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Culvert |
Steel Culvert | linear ft. | 106 | 104 | 2 | 0 | 0 |
Steel Protective Coating | sq. ft. | 2,840 | 2,832 | 0 | 0 | 8 |