US74 US76 EB over HOOD CREEK
Map
Coordinates:
+34.27844, -78.1256834°16'42" N, 78°07'32" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US74 US76 EB over HOOD CREEK |
Structure number: | 000000000190004 |
Old structure number: | 000000000019004 (from 1992 edition) |
Location: | 0.9 MI E JCT NC87 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 36.1 ft. [11.0 m] |
Total length: | 112.9 ft. [34.4 m] |
Roadway width between curbs: | 39.7 ft. [12.1 m] |
Deck width edge-to-edge: | 42.7 ft. [13.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1968 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 3 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: March 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 9,500 [as of 2013] |
Truck traffic: | 14% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 90.5 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2017 | Fair | Fair | Good | Good | 9500 | 90.5 |
March 2015 | Fair | Fair | Good | Good | 9500 | 90.5 |
March 2013 | Fair | Fair | Fair | Fair | 9500 | 25.0 |
March 2011 | Fair | Fair | Fair | Fair | 10000 | 78.5 |
April 2009 | Fair | Satisfactory | Fair | Satisfactory | 8500 | 80.4 |
June 2007 | Poor | Satisfactory | Poor | Satisfactory | 8500 | 63.2 |
January 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 8500 | 92.0 |
January 2003 | Fair | Satisfactory | Satisfactory | Satisfactory | 7500 | 92.5 |
February 2001 | Fair | Satisfactory | Satisfactory | Satisfactory | 7450 | 92.5 |
October 1998 | Fair | Satisfactory | Satisfactory | Satisfactory | 7450 | 92.5 |
February 1997 | Fair | Satisfactory | Satisfactory | Satisfactory | 7150 | 92.6 |
March 1995 | Fair | Satisfactory | Satisfactory | Satisfactory | 7150 | 92.8 |
March 1993 | Fair | Satisfactory | Satisfactory | Satisfactory | 6400 | 93.1 |
February 1991 | Fair | Satisfactory | Satisfactory | Satisfactory | 11600 | 89.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 678 | 0 | 678 | 0 | 0 |
Steel Protective Coating | sq. ft. | 5,634 | 4,956 | 0 | 678 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 4,782 | 2,429 | 1,753 | 600 | 0 |
Substructure |
Prestressed Concrete Column | each | 10 | 0 | 10 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 90 | 39 | 0 | 51 | 0 |
Prestressed Concrete Pile | each | 28 | 18 | 10 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 174 | 169 | 5 | 0 | 0 |
Bearings |
Movable Bearing | each | 12 | 0 | 12 | 0 | 0 |
Steel Protective Coating | sq. ft. | 24 | 0 | 0 | 24 | 0 |
Fixed Bearing | each | 12 | 0 | 12 | 0 | 0 |
Steel Protective Coating | sq. ft. | 24 | 0 | 0 | 22 | 2 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 228 | 227 | 1 | 0 | 0 |