NC12 over THE SLASH
Map
Coordinates:
+35.21824, -75.6887535°13'06" N, 75°41'19" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | NC12 over THE SLASH |
Structure number: | 000000000550008 |
Old structure number: | 000000000055008 (from 1992 edition) |
Location: | 0.1MI S. JCT SR 1248 |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 17.1 ft. [5.2 m] |
Total length: | 86.0 ft. [26.2 m] |
Roadway width between curbs: | 27.6 ft. [8.4 m] |
Deck width edge-to-edge: | 34.5 ft. [10.5 m] |
Owner: | State Highway Agency [01] |
Year built: | 1956 |
Year reconstructed: | 1960 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 5 |
Main spans material: | Wood or timber [7] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: June 2017
Good/Fair/Poor Condition: | Poor |
Status: | Open, would be posted or closed except for temporary shoring [D] |
Average daily traffic: | 3,800 [as of 2015] |
Truck traffic: | 7% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Serious [3 out of 9] |
Structural appraisal: | Basically intolerable requiring high priority of replacement [2] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 15.5 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2017 | Poor | Good | Fair | Serious | 3800 | 15.5 |
June 2015 | Poor | Fair | Fair | Serious | 3400 | 14.2 |
June 2013 | Poor | Fair | Fair | Serious | 3400 | 14.2 |
June 2011 | Poor | Fair | Fair | Serious | 4200 | 12.6 |
June 2009 | Fair | Fair | Satisfactory | Fair | 4800 | 64.1 |
November 2007 | Fair | Fair | Satisfactory | Fair | 5400 | 64.0 |
April 2005 | Fair | Fair | Satisfactory | Fair | 6100 | 62.4 |
June 2003 | Fair | Fair | Satisfactory | Fair | 5500 | 64.8 |
May 2001 | Fair | Fair | Satisfactory | Fair | 6200 | 64.6 |
May 1999 | Fair | Fair | Satisfactory | Fair | 3700 | 65.2 |
May 1997 | Fair | Satisfactory | Satisfactory | Fair | 6300 | 65.6 |
May 1995 | Fair | Satisfactory | Satisfactory | Fair | 6100 | 65.6 |
May 1993 | Fair | Satisfactory | Satisfactory | Fair | 2800 | 58.7 |
July 1991 | Fair | Satisfactory | Satisfactory | Fair | 2800 | 58.7 |