US401 NC39 NC56 over TAR RIVER
Map
Coordinates:
+36.09450, -78.2976736°05'40" N, 78°17'52" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US401 NC39 NC56 over TAR RIVER |
Structure number: | 000000000690033 |
Location: | 0.3 MI. S. JCT. NC56 |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 58.1 ft. [17.7 m] |
Total length: | 300.9 ft. [91.7 m] |
Roadway width between curbs: | 75.8 ft. [23.1 m] |
Deck width edge-to-edge: | 83.7 ft. [25.5 m] |
Skew angle: | 20° |
Owner: | State Highway Agency [01] |
Year built: | 1982 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 5 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: May 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 19,000 [as of 2015] |
Truck traffic: | 14% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 98.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2017 | Fair | Satisfactory | Satisfactory | Satisfactory | 19000 | 98.2 |
May 2015 | Fair | Satisfactory | Good | Good | 20000 | 98.1 |
May 2013 | Fair | Fair | Good | Good | 21000 | 95.0 |
May 2011 | Fair | Fair | Good | Good | 22000 | 94.9 |
May 2009 | Fair | Fair | Very Good | Good | 19000 | 95.3 |
June 2007 | Fair | Fair | Very Good | Satisfactory | 21000 | 95.0 |
April 2005 | Fair | Good | Satisfactory | Good | 19000 | 96.3 |
July 2003 | Good | Good | Very Good | Good | 20000 | 94.1 |
July 2001 | Good | Good | Very Good | Good | 19000 | 94.3 |
October 2000 | Good | Good | Very Good | Good | 21000 | 94.0 |
March 1998 | Good | Good | Very Good | Good | 15400 | 95.8 |
January 1992 | Good | Good | Very Good | Good | 15200 | 97.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 3,300 | 3,285 | 10 | 5 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 25,148 | 2,647 | 22,500 | 1 | 0 |
Substructure |
Reinforced Concrete Column | each | 8 | 1 | 7 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 200 | 199 | 1 | 0 | 0 |
Steel Pile | each | 32 | 32 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 516 | 401 | 98 | 17 | 0 |
Joints |
Pourable Joint | linear ft. | 340 | 195 | 60 | 0 | 85 |
Compression Joint | linear ft. | 170 | 82 | 88 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 110 | 110 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 302 | 132 | 170 | 0 | 0 |
Other Material Bridge Rail | linear ft. | 302 | 302 | 0 | 0 | 0 |