Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR1242 over YELLOW CREEK |
Structure number: | 000000000750004 |
Location: | 75 FT.W.JCT.SR1249 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 34.1 ft. [10.4 m] |
Total length: | 36.1 ft. [11.0 m] |
Roadway width between curbs: | 24.3 ft. [7.4 m] |
Deck width edge-to-edge: | 25.3 ft. [7.7 m] |
Owner: | State Highway Agency [01] |
Year built: | 1974 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Wood or Timber [8] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: June 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 170 [as of 2013] |
Truck traffic: | 6% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
Sufficiency rating: | 79.6 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2017 | Fair | Good | Fair | Fair | 170 | 79.6 |
June 2015 | Fair | Good | Good | Fair | 170 | 80.3 |
June 2013 | Fair | Good | Good | Fair | 280 | 75.4 |
June 2011 | Fair | Good | Good | Fair | 380 | 75.3 |
June 2009 | Fair | Good | Good | Satisfactory | 380 | 86.2 |
August 2007 | Good | Good | Good | Good | 280 | 86.4 |
July 2005 | Good | Very Good | Good | Good | 280 | 85.9 |
June 2003 | Good | Very Good | Good | Good | 260 | 85.9 |
July 2001 | Good | Very Good | Good | Good | 260 | 85.9 |
July 1999 | Good | Excellent | Good | Good | 200 | 90.5 |
June 1991 | Fair | Good | Satisfactory | Very Good | 300 | 73.5 |