SR1222 over UPPER LITTLE RIVER
Map
Coordinates:
+35.40699, -79.0625135°24'25" N, 79°03'45" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR1222 over UPPER LITTLE RIVER |
Structure number: | 000000000850044 |
Old structure number: | 000000000085044 (from 1992 edition) |
Location: | 0.7 MI. S. JCT. SR1279 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 43.0 ft. [13.1 m] |
Total length: | 137.1 ft. [41.8 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 27.2 ft. [8.3 m] |
Skew angle: | 30° |
Owner: | State Highway Agency [01] |
Year built: | 1986 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 9 / H 10 [1] |
Number of main spans: | 3 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Slab [01] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: May 2018
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 2,800 [as of 2015] |
Truck traffic: | 6% of total traffic |
Deck condition: | Very Good [8 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Very Good [8 out of 9] |
Structural appraisal: | Equal to present desirable criteria [8] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 79.7 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2018 | Good | Very Good | Very Good | Very Good | 2800 | 79.7 |
May 2016 | Good | Good | Good | Good | 150 | 94.4 |
May 2014 | Good | Good | Good | Good | 150 | 94.4 |
May 2012 | Good | Good | Good | Good | 150 | 94.4 |
June 2010 | Good | Good | Good | Very Good | 150 | 94.4 |
July 2008 | Good | Good | Good | Very Good | 150 | 94.4 |
May 2006 | Good | Good | Good | Very Good | 150 | 94.4 |
April 2004 | Good | Good | Good | Very Good | 150 | 94.4 |
May 2002 | Good | Good | Good | Very Good | 150 | 94.4 |
February 2000 | Good | Good | Good | Very Good | 150 | 94.4 |
January 1998 | Good | Good | Good | Very Good | 150 | 94.4 |
January 1996 | Good | Good | Good | Very Good | 150 | 92.4 |
January 1994 | Good | Good | Good | Very Good | 150 | 92.4 |
January 1992 | Good | Good | Good | Very Good | 150 | 92.4 |